User guide

M&C TechGroup Germany GmbH • Rehhecke 79 • 40885 Ratingen • Germany
info@mc-techgroup.com • www.mc-techgroup.com • Fon +49 2102 935-0 • Fax +49 2102 935-111
2.12
* Standard, ** optional
Technical Data
Technical specications and illustrations are without
obligation, subject to modications. 10.04/11.12
Gas sample probe type SP3200V (up to 185 °C) SP3200 (more than 185 °C)
Part No. 20S5705 20S5700
Weather protection shield yes
Filter housing material Stainless steel 316 / 316Ti
Sealing materials Graphite, FPM Graphite
Probe flange sealing material Graphite
Pre-filter / sample tubes optional, see data sheet 2-1.1.0.6 and 2-1.1.0.8
Sample pressure max. 0,5-6 bar
Ambient temperature -20 °C to +60 °C
Permissible process gas temperature depending on the temperature class, however max. 200°C at the probe entry
Filter chamber volume 120 cm
3
Filter element, porosity F-3SS150= stainless steel*, 3 micron S-2K150= ceramic**, 2 micron
Sample gas outlet connection 1x 1/4“ NPTi for max. 8mm-tube connectors
Connection gas outlet at option RS 6 mm Swagelok connector
Mounting flange DN65 PN6, FormB, SS316Ti* >DN or ANSI possible**
Weight 7 kg
Option heating type HEX5 HEX5-1.08 HEX5-2.08
Part No. 20S9650 (a) 20S9655 (a)
Mounting controller in the Ex-zone 2 and 22
Control electronic
Power supply 240V 50/60Hz or 120V 50/60Hz (a)
Electrical connection cable gland, terminal range 6-12mm, terminals max. 4mm
2
Marking
II 3 G Ex nA nC nL IIC T5 to T2, II 3 D Ex tD A22 IP65 T75°C to T235°C
Class I, Division 2, Groups A/B/C/D, T5 - T2B
Power max. 800 W (240V), max. 830 W (120V)
Case protection IP65; EN60529
Operating temperature 0 - max. 230 °C
Ambient temperature 0 °C to +50 °C controller: 0 °C bis +50 °C, heater: -20 °C bis +70 °C
Low temperature alarm contact -5 °C to Tset make contact potential free with breaking capacity 250V 3A AC, 0,25A DC
Option back purge unit type RS RS
Part No. 20S5560 (a)
Power supply 230V 50/60Hz 9W or 115V 50/60Hz 9W (a)
Electrical connection cable 3x1mm
2
Marking
II 3GD T4
Connection G 1/2”i at the buffer vessel
Max. back purge pressure 6 bar abs.
Volume buffer vessel 2 liters
Ambient temperature -20°C to 60°C
Option 2-way-ball valve in the probe entrance /VA
Part No. 20S9050
Operating temperature -20°C up to 185°C
Option 2/3-way-ball valve in the probe entrance /3VA
Part No. 20S9325
Backflush / Test gas connection 6mm tube
Operating temperature -20°C up to +185°C
Option pneum. drive for ball valve /VA o. /3VA MS1
Part No. 20S9055
Connection control air G1/4” i
Pressure control air 5-10 bar
Option valve for blowback or calibration gas 1/4” /R
Part No. 20S9045
Opening pressure >0,7 bar
Connection 6mm tube
Maximum blow back pressure 6 bar abs.
Maximum operating temperature +185 °C