Operator's manual Manual

7
Gas sampling and gas conditioning technology 2-1.1.5.1-ME
6 INTRODUCTION
The M&C gas sample probes type SP2600-H.. are based on the patented probe SP2000-H and are
used for continuous gas sampling in processes with a high extent of dust, high temperature and/or
high gas moisture.
6.1 SERIAL NUMBER
The type plates are to be found where the electrical connection box is placed.
NOTE!
Please indicate the serial number of the equipment in case of any question
and when ordering spare parts.
7 APPLICATION
Due to its large filter surface and the possibility to back-purge the filter element, the probes SP2600-
H/C/I/BB/F.. achieve a high service life especially in cases where no pre-filter can be applied. For this
purpose, a back-purge valve and a pneumatic stop valve for the sample gas outlet is integrated in the
probe.
Version SP2600-H/C/I/BB/F/0,1GF is suitable for dusts with extremely fine particles up to 0,1 µm and
version SP2600-H/C/I/BB/F/1K190 can be very efficiently back-purged thanks to the double-ply filter
element and an external filter membrane of 1 µm porosity.