Manual
M&C TechGroup Germany GmbH • Rehhecke 79 • 40885 Ratingen • Germany
info@mc-techgroup.com • www.mc-techgroup.com • Fon +49 2102 935-0 • Fax +49 2102 935-111
2.8
Technical Data
Technical specications and illustrations are without
obligation, subject to modications. 10.04/06.06
Probe series SP
®
compact version SP 2100-H
Part No. 10S1000
10S1100
Sample tube Type SS, stainless steel 316Ti, length 1 m*
no
Sample temperature max. 600 °C*
Sample pressure 0.4 to 2 bar abs.
Ambient temperature -20 °C to +60 °C
Recommended for dust loadings up to 2 g/m
3
*
Filter chamber volume 120 ml
Filter element S-2K 150, filter porosity 2 µm, ceramic
Probe heating temperature +180 °C self-regulating
Ready for operation after 2 hours
Temperature alarm contact, alarm point <160 °C, NO
Temperature alarm, contact rating 250V-3A AC, 30V-3A DC
Connection sample outlet 1/4"-NPT inside, for max. 10 mm tube connectors
Power supply 110 up to 240V 50 / 60Hz
Power consumption start up: 400VA, usual: 100VA, (fuse 6A)
Electrical connection terminals max. 2,5 mm
2
, 2x PG11 cable gland
Electrical equipment standard EN 61010, EN 60335-1
Degree of protection IP54, EN 60529
Mounting flange DN65 PN6,B stainless steel 316Ti
Material of sample contacting parts SS 316 / 316Ti, FPM, ceramic
Weight 9 kg
Options
10S9005 Calibration flange, DN65PN6 with 1/8“NPT connection inclusive flange gasket and screw set
M12x80.
* Standard, other versions on request.
∆P and T90 at flow of: 100 200 500 1000 Nl/hr
∆P pressure loss with new filter element S-2K150 7 11 20 35 mbar
T
90
time – without sample tube/prefilter – 6,0 3,5 1,0 < 0,5 sec
Dimensions
140
ø 160
1000
280
ø 25
sample out
sample out
Dimensions in mm