Owner manual

M&C TechGroup Germany GmbH • Rehhecke 79 • 40885 Ratingen • Germany
info@mc-techgroup.com • www.mc-techgroup.com • Fon +49 2102 935-0 • Fax +49 2102 935-111
9.4
Technical specications and illustrations are without
obligation, subject to modications. 09.96/11.06
Attachment of flow monitor
FA-1,bi to flowmeter FM10
Optical bi-stable flow alarm sensors series FA
Technical Data
Alarm
O.K.
Flow alarm sensors type FA-1,bi FA-2,bi FA-3,bi
Part No. 02E1000 02E2000 02E3000
Measuring tube 5-14 mm 13-27 mm 26-55 mm
Dimensions W x D x H in mm 35 x 23 x 15 63 x 40 x 22 103 x 75 x 25
Weight 50 g 100 g 200 g
Operating temperature -25 °C to +60 °C
Storage temperature -25 °C to +70 °C
Electrical connection 3 m connection cable standard; 4.5 mm ø, 4 core (each additional meter of sensor connection cable = Part No:
02E9000, max. 10 meters) (>10 meters = with pre-amplifier K-FA.. max. 200 meters)
Mounting with clamping screw
Function bi-stable and mono-stable
Power supply voltage from FA.. electronic controller
Protection type IP65 EN 60529
Material aluminium-anodized, epoxy, PVC cable, semi-conductors