SmartGrill Manual

Gasconversion kitsareavailablefromLynxgrills toallow
theSmartGrillbyLynx™tooperateoneithernaturalgas
or
liquidpropanegas.
Thekit,availablefromLynxGrillsoryour
dealer,mustbeinstalledbyaqualiedtechnician
AllInstallaonandallinstallaonpartsmustconformtolocal
codeswiththeNaonalElectricalCodeANSIZ223.1/NFPA70
latestedionandtheNaonalfuelGasCodeANSIZ223.1/NFPA
54intheU.S.andCGAB149.1/.2inCanada.
CanadianinstallaonsmustconformtoCGAB149.1/.2natural
gas/propaneinstallaoncode.(Canada)
Therangplatelistsserialnumbers,modelnumbers
andgastypeandis locatedinone ormoreofthefol
lowing
places:

Aachedto the underside of the drip tray

On the back of the Care & Usemanual

OnthePCcase
The SmartGrill by Lynx
is factory set to use either
liquid propane or natural gas. It is critical that the gas
you use matches that for which the grill was set up.
You
can verify this by checking the rating plate.
Fuel
WC Max Inlet
WCMinUn
der
FullLoad
NatGas
7in
4in
LP
14in
11in
Ensurethatthegassuppliedmeetswiththeminimum
pressurerequirements.Donotoperatethegrillwith
anygasotherthanthatforwhichthegrillhasbeenset
WaterColumnRequirementsTable:
Boththeregulatorandthemanifoldoriceshavebeen
tunedforthetypeofgasspecied
ontherangplate.
Lynxrecommendsthatonlyqualiedprofessionalsperform
therequiredplumbingonthisproduct.
Toensuresasfactoryperformance,thegassupplylinemust
besizedtoaccommodatethetotalBTUrequirementsofall
thegasredequipmentthatwillbeconnectedtothatline.

Innocaseshouldpipelessthan¾”insidediameteror1”
outsidediametereverbeusedtoconnectthisproduct.
 CalculatethetotalBTUoutputofallequipmentand
referto“INDEX:“GasSupply LineRuns:forallowable
rundistancesfor¾”pipe.Failuretomeetthese
minimumrequirements
mayreduceperformanceofthe
grillandotherappliancesrunningonthatsupplyline.
 Alwayskeepsupplylinerunsasshortaspossible.(See
INDEX:“BTUOutput”forspecicmodeloutputs)
 Agasshutoffvalvemustbeinstalledinaneasily
accessiblelocaonbyaquali
edplumber.
 Keepthreadingcompoundoffthersttwopipethreads
toavoidhavinganysmallpiecesofcompoundbreak
looseandclogaburnervalveororice.Donotuse
threadingcompoundonanyarengs.
Forbuiltininstallaons,itisrecommendedthatany
exible
pipeusedbekeptasshortaspossible.(SeeINDEX:“Gas
Connecons”fortypicalpermanenthookup.)
GASCONVERSIONKITS
NEVERCONNECTAGASLINEDIRECTLYTOTHESMARTGRILLBYLYNX™.APRESSUREREGULATORMUSTBEINSTALLEDONALL
GASEQUIPMENT.ALLLOCALCODESREQUREITANDLYNXGRILLSSUPPLIESTHECORRECTREGULATORFORUSEWITHYOU
GRILL.REMOVINGORFAILINGTOINSTALLTHEPRESSUREREGULATORCANRESULTINFIREAND
SERIOUSPERSONALINJURY
ANDWILLVOIDTHEWARRANTY.
WARNING
NATURALGAS
Keeplasttwo
threadsclean
Forfreestandingunitsusingnaturalgas,lynxstrongly
recommendsusingaquickdisconnectkit.
ThisQuickDisconnectKit(part#LQD)isavailablefrom
Lynxoryourdealer.
GASCONNECTIONS