Use and Care Guide

8
|
Care & use/ FIre PIT InsTallaTIon
InSTAllInG THE lP CYlInDER...continued
The LP tank is brought into the fire pit enclosure and
secured to the base by at the bottom ring of the cylinder.
The tank retention bolts are screwed into the bottom collar
of the tank to hold it in place.
Connect the LP hose and regulator assemble to the LP Cyl-
inder. Do not use tools when making this connection, the
knob must be hand tightened only. Make sure the burner
control valve is in the OFF position before opening the
cylinder valve.
Step 1
Step 2
Safety PrecautionS
Inspect the LP gas hose and connections before each use. If there is any damage from normal operating conditions,
weather, rodents or other adverse conditions so not use the hose. Turn OFF the LP tank valve and replace the hose and
regulator assembly. Replacement parts are available from the manufacturer.
Before using your fire pit you must test all gas connection to ensure leak free connections. Gas connections can be
tested with a solution of 1 part dish soap to 3 parts water. Turn on gas at the cylinder gas valve. Brush or spray the solu-
tion on all connections and look for the formation of bubbles. NEVER USE AN OPEN FLAME TO CHECK FOR LEAKS.
If you find any leaks, tighten the connections and retest. If you cannot stop the leak, turn of the gas at the cylinder gas
valve and call a qualified repair technician, or contact Lynx Grills to arrange a service call.
Inspect the burners assembly regularly for damage. Clean any blocked ports. Be aware that insects like to make webs
inside burner assemblies and hoses.