Manual
22
|
CARE & USE/INSTALLATION
FINAL CHECKS
LEAK TESTING
Leak Test Procedure:
• Create a soapy solution of 1 part soap and 3 parts water.
• Confirm that all control knobs are in the off position.
• Turn on the fuel supply. For natural gas, turn the valve
handle 1/4 turn to align with the gas flow.
• For L.P., turn the cylinder valve knob counter clockwise
one full rotation.
• Apply the soap solution generously by paint brush or
squirt bottle on all connections and fittings.
• If bubbles appear to “grow” on any of the connections,
you have a gas leak. IMMEDIATELY turn off the gas
supply.
Fixing a Gas Leak:
• Shut off the gas supply
• Turn all smoker controls to the “ON” position to purge
the smoker of any gas build-up, then turn the controls
back “OFF”.
• Wash off the soapy solution with cold water and dry.
• Tighten the loose joint, or replace the faulty part with
manufacturer-recommended replacement parts.
• DO NOT attempt to repair the L.P. cylinder valve if it is
damaged. The only way to safely resolve a damaged
cylinder is to REPLACE IT.
• Repeat the leak test to ensure that no leaks are present.
IMPORTANT:
Make sure the owner knows where the main gas supply
shut off valve is located.
Finally, for safety and for proper use & care, you must
leave this manual with the owner. Make sure you advise
them to keep it for future reference.
For technical support and customer service, call:
Lynx Customer Care Department
7300 FLORES STREET
DOWNEY, CA 90242
PH.: 562-299-6900
TOLL FREE: 888-289-5969
FAX: 562-299-6978
To prevent fire or explosion hazard, DO NOT
smoke or allow any potential source of ignition
(sparks, electrical arcing, etc) in the area while
performing a leak test. Leak tests should be
conducted outdoors only. Never conduct a leak
test using fire or flame.
DANGER!