Manual

22
|
CARE & USE/INSTALLATION
LEAK TESTING
Leak Test Procedure:
Create a soapy solution of 1 part soap and 3 parts water.
Confirm that all control knobs are in the off position.
Turn on the fuel supply. For natural gas, turn the valve
handle 1/4 turn to align with the gas flow.
For L.P., turn the cylinder valve knob counter clockwise
one full rotation.
Apply the soap solution generously by paint brush or
squirt bottle on all connections and fittings.
If bubbles appear to “grow” on any of the connections,
you have a gas leak. IMMEDIATELY turn off the gas
supply.
Fixing a Gas Leak:
Shut off the gas supply
Turn all smoker controls to the “ON” position to purge
the smoker of any gas build-up, then turn the controls
back “OFF”.
Wash off the soapy solution with cold water and dry.
Tighten the loose joint, or replace the faulty part with
manufacturer-recommended replacement parts.
DO NOT attempt to repair the L.P. cylinder valve if it is
damaged. The only way to safely resolve a damaged
cylinder is to REPLACE IT.
Repeat the leak test to ensure that no leaks are present.
IMPORTANT:
Make sure the owner knows where the main gas supply
shut off valve is located.
Finally, for safety and for proper use & care, you must
leave this manual with the owner. Make sure you advise
them to keep it for future reference.
For technical support and customer service, call:
Lynx Customer Care Department
7300 FLORES STREET
DOWNEY, CA 90242
PH.: 562-299-6900
TOLL FREE: 888-289-5969
FAX: 562-299-6978
To prevent fire or explosion hazard, DO NOT
smoke or allow any potential source of ignition
(sparks, electrical arcing, etc) in the area while
performing a leak test. Leak tests should be
conducted outdoors only. Never conduct a leak
test using fire or flame.
DANGER!