Manual

CARE & USE/INSTALLATION
|
19
Never run flex hose behind the firebox, run the hose at an angle, straight
down, or out of the back.
GAS CONNECTIONS ...continued
Insert the regulator inlet into the cylinder valve and turn the
black coupler clockwise until the coupler is hand tight. Do
not over-tighten this connection.
To disconnect the coupler, first make sure the main cylinder
valve is turned off. Grasp the coupler and turn counter
clockwise. The inlet will then disengage.
Always leak-test the
connection after
refilling or exchanging
LP cylinders. (See
INDEX: “Leak Test” for
further details.)
GAS LINE PURGING
You should purge the gas line of air before attempting to
light the smoker.
Make sure the smoker touch pad is off.
Disconnect the line from the manifold.
Slowly turn on the main gas supply.
GAS CONVERSION KITS
Gas conversion kits are available from Lynx Grills to
allow the smoker to operate on either Natural gas
or LPG. These kits should be installed by a qualified
technician or certified plumber.
The kits come with complete installation instructions.
These instructions should be read completely and
fully understood before installing the conversion kit.
NG AND BULK LP BUILT-IN INSTALLATION
Shut off the gas supply at the main
valve.
If connecting to a bulk propane tank,
disconnect the brass elbow, hose
and regulator from the smoker.
Remove all the fittings from the
smoker manifold.
Connect the gas supply to the
smoker as shown in the diagram on
this page.
Turn the gas supply on and leak test
all connections. (See INDEX: “Leak
Test” for further details.)
NG/BULK LP REGULATOR
LP REGULATOR
As soon as you smell gas, shut off the supply.
Reconnect the line and test for leaks.
Turn the gas supply back on slowly, and wait at least
5 minutes before attempting to light the burner.
Inline Regulator
P/N 30781
Smoker Manifold
1/2” MIP
Fitting
Flexible Gas Line to Inlet
1/2” MxF
Street
Elbow
Inline Regulator
P/N 30781
Smoker Manifold
Flexible Gas Line to Inlet
1/2” FxF
Street
Elbow
1/2” MIP
Fitting
1/2” MxM
Nipple