Manual

Lynx Page 19 Rev. 3/06/08
Lighting and Shutdown Instructions
1. Lighting
a. Open manual gas supply valve (ensure gas supply lines have been
purged).
b. Turn on switch to energize electric supply.
c. The electronic control module will time begin the ignition period in 3
seconds.
d. The gas valve will open and ignition spark will commence and continue
for 20 sec.
e. If flame starts and “is detected”, flame will continue until turned off.
f. If no flame is detected, the gas valve will close after 20 sec. A “wait’
period commences and lasts approximately 5 sec. and a second trial for
combustion commences. The electronic control will attempt three trials
for ignition before locking out for approximately 5 minutes at which time it
will automatically try again.
Electronic control of heater can be re-set by de-energizing and re-energizing electric
power.
2. Shut Down
a. Turn off power to electronic control.
b. For longer periods of shut down, also close manual gas supply valve.