Specification Sheet
FOR MORE INFORMATION, PLEASE CALL 1.888.289.5969 OR VISIT WWW.LYNXGRILLS.COM
Lynx Grills Infrared Electric Heaters may be flush-mounted into a non-sloped ceiling.
• Choose from two sizes: a 39” or 61” frame, and from wattages ranging from 4,000–6,000
watts.
• Installation requires a flat ceiling and minimum 2” x 8” studs, where the heater can face
straight down when recessed.
• Avoid flush mounting the heater close to a ceiling fan or light fixture.
• You will need to hire a licensed contractor in order to complete a flush mount installation.
5/8" DRYWALL
1 HOUR FIRE RATING
LINE ENTIRE CAVITY
(5 SIDES)
MINIMUM
OPENINGS
2 X 8 STUDS
65.25” for 61” Heater
11.75
MINIMUM
43” for 39” Heater
1 HOUR FIRE RATING
5/8" DRYWALL
SUBFLOOR
JUNCTION BOX MOUNTED OUTSIDE
THE LINED POCKET ON TOP OR SIDE
FIXTURE WHIP w/ HIGH TEMPERATURE CONNECTORS
CONNECTION MADE AT JUNCTION BOX (provided)
2 X 8 STUDS
MINIMUM
FLUSH MOUNT YOUR HEATER IN FOUR SIMPLE STEPS
Step 1
Frame the pocket that will house the heater with a one hour-rated fire containment box.
Step 2
The junction box must be mounted outside of the lined pocket. You can choose to mount the
junction box in a variety of locations, depending upon where you’ll be accessing it.
LYNX GRILLS FLUSH MOUNT HEATER KITS
INSTALLATION INSTRUCTIONS
FLUSH MOUNT HEATER KITS
INSTALLATION INSTRUCTIONS