Care & Use / Installation
SEDONA CARE & USE/INSTALLATION 
|
9
CUT-OUT DIMENSIONS FOR BUILT-IN GRILLS
Note: For Natural Gas grills, the manufacturer 
recommends using 3/4” gas supply lines.
9/16” for Grills
1/2” for Complementary Products
Depth equals
countertop 
overhang
Dim C to cabinet face
COUNTERTOP 
NOTCH DETAIL
Only required if island 
countertop overhangs 
the face of the island
NOTE: Insulating jacket 
required for all grills 
installed into a combustible 
enclosure.
Note: Side burners may be rotated 90 degrees.
INSULATING JACKET
An enclosure for an LP-gas cylinder shall be ventilated by openings at 
both the upper and lower levels of the enclosure. The effectiveness of the 
opening(s) for purposes of ventilation shall be determined with the LP-gas 
supply cylinder in place. This shall be accompanied by one of the following: 
a) One side of the enclosure shall be completely open; or
b)  For an enclosure having four sides, a top and a bottom:
1. At least two ventilation openings shall be provided in the side walls of the 
enclosure, located within 5 in (217 mm) of the top of the enclosure, equally 
sized, spaced at a minimum of 90 degrees (1.57 rad), and unobstructed. The 
opening(s) shall have a total free area of not less than 1 in 2/ lb (14.2 cm2/kg) of 
stored fuel capacity.
2. Ventilation opening(s) shall be provided at floor level of the enclosure and shall 
have a total free area of not less than 1/2 in 2/lb (7.1 cm2/kg) of stored fuel 
capacity. If ventilation openings at floor level are in a side wall, there shall be 
at least two openings. The bottom of the openings shall be 1 in (25.4 mm) or 
less from the floor level and the upper edge no more than 5 in (127 mm) above 
the floor level. The openings shall be equally sized, spaced at a minimum of 90 
degrees (1.57 rad) and unobstructed.
3. Every opening shall have minimum dimensions so as to permit the entrance of 
a 1/8 in (3.2 mm) diameter rod.
4. Ventilation openings in side walls shall not communicate directly with other 
enclosures of the outdoor cooking gas appliance.
Keep the ventilation openings of the cylinder enclosure free and clear from 
debris.
A
4.5”
5”
3”
C
B
BUILT-IN GRILL
Model   A   B   C
L500  29.00  10.00  21.25
L600  35.00 10.00 21.25
L700  41.00 10.00 21.25
COMPLEMENTARY PRODUCTS
Model   A   B   C
LSB501  11.00  4.00  16.00
LSB502  21.00  4.00  16.00
LDR424  22.00 19.00 –
LDR530  28.25  19.00  – 
LDR636  33.75 19.00 –
LSA530  28.25  19.00  20.00
LSA636  33.75  19.00  20.00
LUD517  17.25  12.75  20.00 
L500REF  21.50  34.00  24.50
BUILT-IN GRILL W/ INSULATING JACKET
Model   A   B   C
LIJ500  36.00  11.62  23.25
LIJ600  42.00 11.62 23.25
LIJ700  48.00 11.62 23.25
A
A
0.56”
Double
Drawers
(LUD)
Single & 
Double Side 
Burner (LSB)
Outdoor
Refrigerator
(L500REF)
Door & Drawer Options
(LDR, LSA or LTA)
CUTOUT NOT
REQUIRED
WITH LIJs
Locate a 110 V 15Amp
GFI outlet for rotisserie  
models.
B
C
A
B
3.50”
3.50”
12.00”
2.00”
34.00”
2.25”
21.50”
A
* When installing the LSB side burners  
  over the refrigerator, the counter top  
  must be at least 37-1/2” above the floor.
UNCONVENTIONAL ISLAND INSTALLS
If building an island that does not conform to the standard 
properties listed in the following pages, please contact Lynx 
Grills at 888-259-5969 to verify all safety requirements 
regarding installation have been met.