MAXIMUM RUNS FOR ALL 
APPLIANCES ON SUPPLY LINE
Run Length 3/4” 
Pipe (in feet)
Max BTU for all 
Appliances on line
10 360,000
20 245,000
30 198,000
40 169,000
50 150,000
60 135,000
70 123,000
80 115,000
MODELSPECIFIC BTU OUTPUTS & MAX. RUNS FOR APPLIANCES
MODELSPECIFIC BTU OUTPUTS
MODEL CERAMIC 
BURNER (Btu) 
ROTISSERIE (Btu) TRIDENT™ (Btu) TOTAL INPUT
L27R 2 @ 25,000  1 @ 14,000  64,000 Btu/Hr
L27TR(F) 1 @ 25,000 1 @ 14,000 1 @ 21,000 60,000 Btu/Hr
L30R(F) 2 @ 25,000  1 @ 14,000  64,000 Btu/Hr
L30TR(F) 1 @ 25,000 1 @ 14,000 1 @ 21,000 60,000 Btu/Hr
L36R 3 @ 25,000 1 @ 14,000 89,000 Btu/Hr
L36TR(F) 2 @ 25,000 1 @ 14,000 1 @ 21,000 85,000 Btu/Hr
L42R 3 @ 25,000  1 @ 16,000  91,000 Btu/Hr
L42TR(F) 2 @ 25,000 1 @ 16,000 1 @ 21,000 87,000 Btu/Hr
L54TR(F) 3 @ 25,000  2 @ 14,000  1 @ 21,000  124,000 Btu/Hr