manual
CARE & USE/INSTALLATION 
|
45
MAXIMUM RUNS FOR ALL 
APPLIANCES ON SUPPLY LINE
Run Length 
3/4” Pipe (in feet)
Max BTU for all  
Appliances on line
10 360,000
20 245,000
30 198,000
40 169,000
50 150,000
60 135,000
70 123,000
80 115,000
MODEL-SPECIFIC BTU OUTPUTS & MAX. RUNS FOR APPLIANCES
MODEL-SPECIFIC BTU OUTPUTS
MODEL  CERAMIC BURNER (Btu)  ROTISSERIE (Btu) TRIDENT ™(Btu) TOTAL INPUT
L27R  2 @ 25,000  1 @ 14,000  64,000 Btu/Hr
L27TR(F)  1 @ 25,000  1 @ 14,000  1 @ 21,000  62,000 Btu/Hr
L30R(F)  2 @ 25,000  1 @ 14,000  64,000 Btu/Hr
L30TR(F) 1 @ 25,000  1 @ 14,000  1 @ 21,000  62,000 Btu/Hr
L36R  3 @ 25,000  1 @ 14,000  89,000 Btu/Hr
L36TR(F) 2 @ 25,000  1 @ 14,000  1 @ 21,000  87,000 Btu/Hr
L42R  3 @ 25,000  1 @ 16,000  91,000 Btu/Hr
L42TR(F)  2 @ 25,000  1 @ 16,000  1 @ 21,000  89,000 Btu/Hr
L54TR(F)  3 @ 25,000  2 @ 14,000  1 @ 21,000  126,000 Btu/Hr