L24TWS & L24TWD Care & Use
Wild Beer Description
Beer, when drawn, is all foam, or too much foam and
not enough liquid beer.
Causes
Beer drawn improperly
Creeping regulator
Applied pressure is set too high
Hot spots in line
Use of non-insulated beer line
Beer runs are too long for proper cooling
Tapped into a warm keg (Should be 34°- 38°
Cooler malfunctioning
Kinks, dents, twists or other
obstructions in line
Faucets in bad, dirty or worn condition
Flat Beer Description
Foamy head disappears quickly;
beer lacks usual zestful brewery fresh flavor
Causes
Dirty glasses (not beer clean)
Sluggish regulator
Applied pressure is set too low
CO
2
is turned off at night
Contaminated air source
(associated with compressed air)
Moisture in air system
Beer too cold
Loose tap or vent connections
Cloudy Beer Description
When beer in glass appears hazy, not clear
Causes
Frozen or nearly frozen beer
Old beer
Beer that has been unrefrigerated for
long periods of time
Dirty glass
Dirty faucet
Unrefrigerated foods placed on top of cold keg
Contaminated air source
False Head Description
Large soap-like bubbles, head dissolves very quickly
Causes
Applied pressure required does not correspond to
beer temperature
Small beer line into a large faucet shank
Beer lines warmer than beer in keg
Dry glasses
Improper pour
Unpalatable Beer Description
Off-Taste
Causes
Dirty or old beer lines
Dirty faucet
Contaminated air source, or unfiltered
Unsanitary bar conditions
When not in use:
We recommend that the CO2 canister be shutoff and the ball valve closed if the Beverage kit will not be used for an
extended period of time. Keep the CO2 tank inside the refrigerator and all connections intact.
The CO2 tank should be replaced or refilled when the CO2 Tank level indicator falls into the red indicator zone (below 300
PSI). Check with your beverage provider for local sources of CO2.
Storage:
For seasonal storage of the Beverage Kit we recommend that the CO2 tank be stored upright in a cool place. The Tower
Base may be disconnected from the keg coupler and removed from the island installation. To help prevent heat loss
replace the black plastic cap into the top of the refrigerator (see page 2 step 1) . The cap may be installed into the top or
from the inside if more convenient. Seal all hoses and connectors in an air tight plastic bag to avoid dirt and insects during
storage. We recommend that you obtain a cleaning kit and purge the fluid lines seasonally. These may be obtained from
your beverage supplier or on line.
Part No.
Description
Qty
Part No.
Description
Qty
1
32413
33845
Tower Assembly
Single Tap, or
Tower Assembly Double Tap 1
9
32404
C02 Cylinder, 5 Pounds, Alum
1
2
80411
Beverage Center Deck Assembly
1
10
33029
33847
Regulator, Single Tap, CO2, or
Regulator Double Tap, CO2 1
3
32414
Tubing, 7/8 OD, x 12 1
11
32403
Keg Coupler, Domestic (Style D)
1
4
32399
Insulation, Tower Armaflex 1
12
33030
Rubber Washer (Coupler) 2
5
L24TWB
Tower Base w/Leveling Feet 4
13
33027
Hose, CO
2
to Coupler 1
6
33010
Base, Spill Tray Insert 1
14
33028
Hose Clamps, CO
2
2
7
33011
Grate, Spill Tray Insert 1
15
33022
Hose, Coupler to Tower 1
8
33031
Faucet Wrench 1
16
33023
Hose Clamps, Tower 1