User's Manual
Reference Manual R FR 5010 Version1.4 
Page 20 
Control Connection 
An external Control Interface is provided on the 
rear termination panel. When an R CT 5020 Rack 
Controller (or R CT 5030 Master Controller) is fitted 
to the rack this port can be used for two primary 
functions: 
1.  When configured as a RS 232 serial port this can 
be connected directly to a PC running the LYNX 
control software. 
2.  When configured for RS 422 operation this port is 
used to daisy chain other racks fitted with R CT 
5020 Rack controllers (up to 15 additional racks) 
Note. Please refer to the R CT 5020 Reference 
Manual for details on how to re-configure the port 
and more detail on the use of this control interface. 
The connection is a 9 pin SubD female connector. 
Function and connection information is described 
below. 
Connections for RS 422 
Connections for RS 232 
Pin 
Number 
Connection 
Pin 
Number 
Connection 
 1  GND Shield  6  GND 
2  TX A 422  7  TX B 422 
3  RX B 422  8  RX A 422 
4 GND  9  GND Shield 
5 GND     
Pin 
Number 
Connection 
Pin 
Number 
Connection 
 1  GND Shield  6  GND 
2 TX 232  7    
3  RX 232  8   
4 GND  9  GND Shield 
5 GND     