User Manual

LS-AES
Page 15
Support
We are devoted to making your experience with LS-AES trouble-free and productive.
If you have questions or comments regarding the operation of your LS-AES please check the
Troubleshooting topics on the Support section of the Lynx web site at:
http://www.lynxstudio.com/support.html
If you are unable to find information about your problem please email us at:
support@lynxstudio.com
In your email message include the following information:
The serial number of your LS-AES and the serial number of your LynxTWO/L22.
Which operating system you are using.
The type of computer you are using.
The name of the application you are using.
A detailed description of the problem including any error messages you received.
We will provide a response in a timely manner.
Telephone support is available by calling (949) 515-8265, ext. 206 from 9AM to 5PM Pacific Time,
Monday through Friday, excluding Holidays. Please have the above information available before
calling.
Digital I/O Port Pinout
DB25 Pin
Signal Connector Pin
DB25 Pin
Signal Connector Pin
1 OUT 4 Hot XLR 2 14 OUT 4 Cold XLR 3
2 OUT 4 Gnd XLR 1 15 IN 4 Hot XLR 2
3 IN 4 Cold XLR 3 16 IN 4 Gnd XLR 1
4 OUT 3 Hot XLR 2 17 OUT 3 Cold XLR 3
5 OUT 3 Gnd XLR 1 18 IN 3 Hot XLR 2
6 IN 3 Cold XLR 3 19 IN 3 Gnd XLR 1
7 OUT 2 Hot XLR 2 20 OUT 2 Cold XLR 3
8 OUT 2 Gnd XLR 1 21 IN 2 Hot XLR 2
9 IN 2 Cold XLR 3 22 IN 2 Gnd XLR 1
10 OUT 1 Hot XLR 2 23 OUT 1 Cold XLR 3
11 OUT 1 Gnd XLR 1 24 IN 1 Hot XLR 2
12 IN 1 Cold XLR 3 25 IN 1 Gnd XLR 1
13 not connected