Owner's Manual
16
BUILT-IN INSTALLATIONS:
Lynx built-in accessories are
intended for installation in a
built-in enclosure constructed
of non-combustible materials.
The accessory drops into the
opening shown in the cutout
detail drawing and hangs from
its counter-top trim. A deck is
not required to support it from
the bottom.
Pay special attention to the
provisions shown for gas line
hook-up.
(See INDEX: “Cut-out
Dimensions for Built-in Grills &
Accessories”)
Installation provisions may be
made for the Power Burner
installation. The Power Burner
cooking height may be reduced
to better accommodate large
cooking pots. Clearances to
combustible material must be
maintained as outlined below.
No combustible material shall
be used in the construction of
a counter top using a recessed
application.
The enclosure should have
ventilation holes to prevent gas
build-up in the event of a leak.
The deck ledges and counter
should be at and level. (Refer
to ANSI Z21.58 Standard for
Outdoor Cooking Gas Appli-
ances, Section 1.7 Enclosures
For Self Contained LP-Gas
Supply Systems or local codes
for additional information.)
The grill accessory may be
powered from either a 120 volt,
60 hertz, 15 amp GFI certied
outlet installed by a qualied
electrician OR it may be
powered directly
from your Lynx
Grill transformer power supply.
When a Lynx grill is not
available or if the grill is
not located close enough
to the grill a Lynx LASK
(Lynx Accessory Switch Kit)
is available as an optional
purchase.
CLEARANCE TO COM-
BUSTIBLE MATERIALS:
Minimum clearance from
the sides and back of the
accessory to adjacent combus-
tible construction below the
top of unit are 12” from the
sides and back.
Dégagement minimal entre
les parois latérales et l’arrière
de l’appariel et la construc-
tion combustible au-dessous
du panneau supérieur de
l’appareil (30 cm à partir des
parois latérales et 30 cm à
partir de l’arrière).
Minimum clearance from sides
and back of unit to adjacent
combustible construction
extending above the unit is
18” from the sides and back.
Dégagement horizontal
minimal entre les parois
latérales et l’arrière de
l’appariel et la construction
verticale combustible au-
dessus de l’appareil (45.7 cm
à partir des parois latérales et
45.7 cm à partir de l’arrière).
Do not use this appliance
under overhead combustible
surfaces.
Ne pas utiliser cet appareil
sous une surface combustible.