User's Manual
2. Block Diagram
2.1. Network Stack Module Block Diagram
3. General Specifications
4. Absolute Maximum Ratings
Parameter
Min
Max
Unit
Storage Temperature
-40
+85
°C
Operating Temperature
-40
+85
°C
VDD Operating Voltage
+2.0
+3.6
V
VFEM Operating Voltage
-0.3
+5.5
V
5. Electrical Characteristics
5.1. Transmitter Specification
Conditions: Vdd = Vfem = 3.3V, temperature = 25 C, 50 ohm matched antenna, unless otherwise specified.
Parameter
Condition
Min
Typ
Max
Unit