6.2 Temperature curve
In order to ensure soldering quality, special attention should be paid to the control of temperature
curve pipes. The soldering profile shown below is only a general recommendation and should be
adjusted according to the specific application and manufacturing.
Figure 6-2 The reference temperature curve
6.3 Device moisture-sensitivity level (MSL)
L710HG module complies with the humidity level 3. At a temperature of <30 degrees and relative
humidity of <60% of the environmental conditions, dry pack to perform J-STD-020C specification
according to IPC / JEDEC standard. At a temperature of < 40 degrees and a relative humidity of <
90% of the environmental conditions, in the case of unopened shelf life of at least six months. After
unpacking, Table6-1 shows the module shelf life at different times corresponding to the level of
humidity.
Table 6-2 Moisture sensitivity level and floor life
The Moisture Sensitivity Level
(MSL)
Floor Life(out of bag) at factory ambient +30
/60%RH
1 RH condition
Unlimited at +30 /85%
2
1 Year
2a 4 weeks
3 168 hours
4 72 hours
5 48 hours
5a
24 hours