Manual

8
displayed, press the ENTER button. The CANCEL , or
BACK SPACE can be used for editing the input line.
4. The LCD will flash POWD”, then display P=_”. Enter
the name of the powder and press the ENTER button.
5. The LCD will flash “WGHT”, then display “W 0.0 gn”.
6. Use the UNIT button, if necessary, to change to grams or
ounces.
7. Enter the charge weight and press the ENTER button.
8. The load is saved. The LCD will now display “MEM=02”
indicating the second memory position, to prompt the user
for the next entry. Enter the next load into memory as
described above.
9. Press the CAL/ZERO button to exit the memory mode.
F. Recall A Load From Memory
1. Press the RECALL button. The LCD will display “C=_ _
_ _”.
2. Press the RECALL button again and the LCD will display
the first cartridge in the memory. Press the ENTER button
to select this cartridge. The LCD will scroll through the
information stored for this cartridge. Press the ENTER
button again to dispense this load.
WARNING: Be sure that the correct powder is in the
reservoir.
3. To scroll through the other loads in memory press the
RECALL button repeatedly. The FAST button and the
TRICKLE button can also be used to scroll through the
memory. Pressing the FAST button will move the display
to the next memory location and pressing the TRICKLE
button will move the display to the previous location.
4. Press the CAL/ZERO button to exit from memory and
return to the standard Scale and Dispense mode.
G. Recall Memory Using A Cartridge Name
1. To recall a load in memory using the cartridge name, press
the RECALL button. The LCD will display “C=_ _ _ _”.