D. Scale and Dispense Mode
1. The scale and dispenser are now active. Place the powder
pan onto the platform and press the CAL/ZERO button to
zero the scale.
2. Place the desired smokeless powder (black powder or
Pyrodex should NEVER be used) into the powder
reservoir.
3. The scale will read in grains (default) unless changed. To
select the weighing unit desired, press the UNIT button to
select the appropriate grains, grams or ounces.
4. Key in the desired charge weight using the keypad. If you
make a mistake press the CANCEL button to clear the
complete charge weight or press BACKSPACE to clear
the last digit. While the desired charge weight is displayed,
press the ENTER button to dispense powder. The
dispenser will stop automatically when the selected charge
weight is reached. We recommend that the first several
charges be placed back into the reservoir. This allows the
1200 DPS to fully stabilize and fill the charge tube with
powder. After a charge is dispensed, the LCD will display
“CT=001” indicating the first charge for 2 seconds. This is
a count of the number of charges that have been dispensed.
5. Press the ENTER button again to dispense another charge
at the selected weight in memory.
6. To pause the dispenser while a charge is being dropped,
press the ENTER button. Press the ENTER button again
to resume charging.
7. The dispenser will continue to drop the selected weight
until it is changed. To change the selected weight, key in a
new weight on the keypad and press the ENTER button.
The dispenser will drop the new selected charge weight.
D-2 Manual - Trickle Mode
To manually dispense a charge, press and hold the FAST
button. The dispenser will run the feed tube at high speed until
the button is released. Press and hold the TRICKLE button to