Manual
10
3. Press the ENTER button to move from cartridge name to
powder to weight.
4. Press the CANCEL button to clear the entire entry or press
the BACKSPACE button to clear the last number or letter.
5. Enter the new information as needed. Press the ENTER
button repeatedly until the next cartridge name appears.
6. Press the CAL/ZERO button to exit from memory and
return to the standard Scale and Dispense mode.
J. Delete Memory
1. Follow steps discussed in F, G or H to select a load in
memory.
2. Press and hold the CANCEL button to delete the selected
load in memory. The LCD will display the next memory
entry.
3. Press the CAL/ZERO button to exit from memory and
return to the standard Scale and Dispense mode.
NOTE: The memory location vacated by deleting a load
will remain open until a new load is entered into
memory at this location. This is to keep the other
memory locations the same. They will not shift up one
location.
Cleaning The 1200 DPS
Caution: Do not turn unit upside down and shake as
this could harm the load cell.
The cleaning procedure listed below may seem difficult,
but after you become familiar with the dispenser it is
relatively easy. The 1200 DPS was designed to be
sufficiently disassembled for thorough cleaning
The 1200 DPS must be cleaned after use or when changing
the type of powder. It is Strongly recommended that
powder NOT be left in the powder dispenser when finished
loading or when putting it away as you may forget what