Operation Manual
V7 Version 3.01 October 2013
Page 30 of 48
Weights must be entered and user should enter ballast in kilograms. There are three
weights to enter. Min. Weight
(Minimum glider weight)
corresponds to the min.load value
and represents the value at which the polar was measured or recalculated. Max. weight
(Maximum glider weight)
is the maximum take-off weight allowed for a glider. It is not used
in the calculation, it is just a reminder to the pilot of the maximum take-off weight. Empty
weight
(Empty glider weight)
is weight of the glider without pilot and ballast. The overload
factor is calculated as:
weightgliderMinimum
ballastWaterweightPilotweightgliderEmpty
overload
..
....
+
+
=
Empty glider weight is a weight of empty glider. This number can be found in a glider
book.
Pilot weight is weight of the pilot with parachute and baggage.
Water ballast is a weight of ballast.
Minimum glider weight is a
weight of empty glider + minimum pilot weight.
This value is
useful for when we want to display ballast in weight (kg or lbs).
Maximum glider weight is MTOW (
max. takeoff weight
) – this value is used only to limit
pilot to enter higher ballast, as is allowed with MTOW.
5.3.10 Flarm
By enabling the item, show flarm warning, Flarm warnings will be shown on the main
screen.
Each warning can be dismissed with push button. Dismiss time is time period during which
the instrument will not give you any warning after pressing dismiss. In the event that
dismiss while circling is enabled, the dismiss period will be extended until end of circling
flight is detected.
5.3.11 Password
There are several passwords which run specific procedures as listed below:
• 00666 Resets all settings to factory default
• 99999 will clean logbook
• 01048 can adjust needle on zero. (necessary only after update to version 2.0)
• 01049 can align airspeed on zero.