2.1.6.6 STOCK CATCH LEVER (11.)
This Lever is is depressed to allow the EMOD stock to move between
detent positions. Depress the lever on either side of the ventral rib
and push/pull the stock
2.1.6.6 STORAGE COMPARTMENT (12.)
Depress the catch to open the storage compartment.
2.1.6.7 BATTERY STORAGE (27.)
Rotate tab while pulling on the storage cap to remove it. Press back
into place. Holds 4x CR123A batteries each.
These apply to the EMOD stock on the R.E.P.R. 12 & 16 onlyNormal setting is the default setting for non-suppressed operation.
R.E.P.R.s are tuned for operation with match grade ammunition with
heavier weight bullets like M118LR or Federal Gold Medal Match
168gr. Ejection with these loads should be at the 4 oโ€™clock position
(with muzzle at 12 oโ€™clock). With higher pressure loads , the ejection
pattern should shift to the 2-3 oโ€™clock position. This indicates that the
bolt carrier velocity is higher than optimal which may increase the
possibility of a bolt-over-base stoppage.
Adverse setting is only used when the weapon is operating
sluggishly due to extreme and/or very low temperature and/or
underpowered ammunition.
When you ๎€žrst shoot your REPR, use the gas block tool to rotate while
the weapon is still warm. Work through each of the settings several
times then lubricate. This will greatly reduce the likelihood that your
regulator will stick in the future.
27.
11.
12.