User Manual

BW/BWS Series Indicator Technical Manual
- 16 -
gra
Gravity
Dual 2
To select dual interval - mode 2
Note: First interval will active in CAP 1
Second interval will active in CAP 2
Count
To check internal counts
Deci
To set decimal points
Div
Di v 1
To
select
first
division
Di v 2
To
select
second
division
Cap
Cap 1
To
select
first
capacity
Cap 2
To
select
second
capacity
Cal
Calibration
gra
Gravity
P3 oth
Lock
To set keypad lock
Options: on / off
anm
To set animal mode.Options: on / off
P4 ST
ST
To set Multiple tare function
Options: on / off
P5 clr
Clr cal
Clear calibration for the record
Clr opt
Clear operation for the record
7. CALIBRATION
To set calibration, turn on the scale.
Press key during the self checking.
Display will be show pn
Press , and to enter, display will be show po chk
Press until display will be show p 2 mod.(These is a switch on the
main board you need to press it then can into the parameter)