Datasheet
https://www.luxonis.com Dec, 2021
3
4 Electrical Characteristics
4.1 Absolute Maximum Ratings
1
SYMBOL
RATINGS
MIN
MAX
UNIT
V
BUS
USB input supply voltage range.
2
3.5
5.5
V
I
VBUS
Maximum input current requirement
2
A
T
stq
Ambient temperature
0
60
C
4.2 Recommended Operating Conditions
1) Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress
ratings only, which do not imply functional operation of the device at these or any other conditions beyond those indicated under
Recommended Operating Conditions. Exposure to absolute-maximum-rated conditions for extended periods may affect device
reliability.
2) According to industry standard Universal Serial Bus (USB) specifications
SYMBOL
RATINGS
MIN
TYP
MAX
UNIT
V
BUS
VBUS input supply voltage
5V
5.25
V
P
Power consumption requirement
4
6
7.5
W
P
IDLE
VBUS idle power draw (Myriad X booted)
2.5
W
T
A
Ambient operating temperature
50
°C