Specification

6 SS-B01 Rev. F 072021
Luxier
Operation
Troubleshooting
COLD (blue)
HOT (red)
1. Turn the handle counter-clockwise from the OFF
position to the BLUE dot (cold water) to start the water
ow. Continue turning the handle to the RED dot (hot
water) to reach the hot water temperature.
(CAUTION: Scalding may occur if the control is set to maximum
temperature.) It is strongly recommended to set the handle halfway
between the BLUE and RED dots as the starting point. Gradually turn
the handle to set the desired water temperature.
2. To turn o the water, return the handle to the OFF
position.
Problem
Shower valve produces loud humming / vibrating noise when water is running
Possible Cause
1. Debris or sediment inside the cartridge, valve body, or plumbing system
2. One or both the plungers inside the stop valves may have shifted (mis-aligned) during transport
Solution: Clean Out Debris and Reset the Plungers
1. Shut o water to the valve
2. Remove Handle and Escutcheon
3. Remove the Threaded Nipple, Stem Extension, and Cartridge Nut and pull out the Cartridge
4. Clean and make sure the Cartridge is free of debris and sediments
5. Remove both Stop valves with an adjustable wrench. (CAUTION: Be careful removing the Plungers
and the tiny Springs when removing the Stop Valves. See Fig. 1)
6. Clean out any remaining debris or sediments inside the valve body
7. Re-install the Stop Valves Assemblies (including the Plungers and Springs) and use a large at head
screwdriver, turn both screws on the stop valves clockwise to close the stop valves completely. Once
the valves are closed, turn the screws counterclockwise to open both valves again. Make sure to fully
open the valves for maximum water ow. This step will reset the Stop Valves. (See Fig. 2)
8. Re-install the Cartridge and assemble the parts
9. Turn of water to the valve and test the unit to complete the service
2
Plunger
Spring
1