Datasheet

LUXEON Rebel Color Porfolio Datasheet DS68 20121219 9
Absolute Maximum Ratings
Table 5.
Parameter Green/Cyan/ LUXEON Rebel ES Red/Deep-Red
Blue/Royal Blue Royal Blue/ES Blue Red-Orange/Amber PC Amber
DC Forward Current (mA) 1000 1000 700 700
Peak Pulsed Forward 1000 1200 700 700
Current (mA)
Average Forward Current (mA) 1000 1000 700 700
ESD Sensitivity < 8000V Human Body Model (HBM) Class 3A JESD22-A114-B
LED Junction Temperature
[1]
150°C 150°C 135°C 130°C
Operating Case Temperature -40°C - 135°C -40°C - 135°C -40°C - 120°C -40°C - 110°C
at 350 mA
Storage Temperature -40°C - 135°C -40°C - 135°C -40°C - 135°C -40°C - 135°C
Soldering Temperature JEDEC 020c 260°C JEDEC 020c 260°C JEDEC 020c 260°C JEDEC 020c 260°C
Allowable Reflow Cycles 3 3 3 3
Autoclave Conditions 121°C at 2 ATM 100% Relative Humidity for 96 Hours Maximum
Reverse Voltage (Vr) LUXEON Rebel Color Portfolio LEDs are not designed to be driven in reverse bias.
Notes for Table 5:
1. Proper current derating must be observed to maintain junction temperature below the maximum.
2. The maximum rating for LUXEON Rebel ES Royal Blue is 1200 mA with peak pulsed forward current not to exceed 60 seconds.
JEDEC Moisture Sensitivity
Table 6.
Soak Requirements
Level Floor Life Standard
Time Conditions
Time Conditions (hours)
1 unlimited [ 30°C / 168 85°C / 85%
85% RH + 5 / -0 RH