User Manual

LuxProducts.com | 29
APPENDIX7.
NOTES:
The G Wire (dark) that previously went to the Fan Terminal
now connects to the Furnace Transformer
The Power Wire (white) connects to both the Fan Terminal
as well as the Cool Terminal (with the Y Wire)
Conventional System Without C-Wire
(AFTER Power Wire) Wiring Diagram
C
C
W1
W1
W2
O/B
1 4 2
Y1
Y1
RC
RC
RH
RH
G
G
3
FAN
POWER
HEAT
COOL
TRANSFORMER
FURNACE
THERMOSTAT
P-WIRE