SPECIFICATION SUBMITTAL
Job Name:
Job Number:
Model Numbers:
Panel Model Numbers
The following model numbers are non-orderable base models for the factory assembled QS DIN panels and must be
configured to order. See Panel Configuration Nomenclature below for all assembly options.
PD2-S-ASM: 16 in (406 mm) Satellite Panel with up to 2 DPMs
PD4-C-ASM: 42 in (1067 mm) Control Panel with up to 4 DPMs and a low-voltage compartment
PD6-S-ASM: 42 in (1067 mm) Satellite Panel with up to 6 DPMs
PD8-C-ASM: 65 in (1651 mm) Control Panel with up to 8 DPMs and a low-voltage compartment
PD8-B-ASM: 65 in (1651 mm) Breaker Panel with up to 8 DPMs and branch circuit breakers
PD10-S-ASM: 65 in (1651 mm) Satellite Panel with up to 10 DPMs
Panel Configuration Nomenclature
Enclosure Sizes
2 = 16 in (406 mm) enclosure (2 DPMs)
4 = 42 in (1067 mm) enclosure (4 DPMs)
6 = 42 in (1067 mm) enclosure (6 DPMs)
8 = 65 in (1651 mm) enclosure (8 DPMs)
10 = 65 in (1651 mm) enclosure (10 DPMs)
Panel Options
B = Breaker Panel (breakers and modules, no control
equipment)
C = Control Panel (control equipment compartment
and modules, no breakers)
S = Satellite Panel
(modules only, no control equipment or breakers)
Branch Circuit Breaker Options (QTY: 8)
15B = 120 V~ 15 A Breakers
20B = 120 V~ 20 A Breakers
Blank = 120 / 277 V~ Feed-through
Feed Types
L3 = 1 Ø 3 W (125 A main lug, breaker panel only)
L4 = 3 Ø 4 W (125 A main lug, breaker panel only)
Blank = Feed-through (20 A per feed maximum)
Enclosure
Size
Panel
Option
Note: The following information is given for general use only. Use Lutron Designer+ to configure panel combinations and for
assistance with specifying module and control equipment. See page 6 and 7 for example configurations.
ALPD____ - __________ -__ -_ -__
DIN Modules
B = Four Output PRO LED
+
Phase Adaptive Dimming
F = Four-Circuit Switching
G = Four-Circuit 0–10 V- / Switching
0 = Open space for expansion
Control Equipment Options
(maximum of 2, controls panel only)
N = 2-Link Processor
R = 1-Link Processor
X = DMX Control
C = Contact Closure Interface
K = Network Interface
A = PoE Switch
0 = Open space for expansion
Wire Landing Boards (1-4, control panels only)
_ = # of QS Wire Landing Boards
Link Power Supply (maximum of 2, control panels only)
L = 75 PDU Power Supply (required if panel contains
processor or PoE Switch)
0 = No Power Supply, open space for expansion
DIN Modules: Type
(Bottom to Top,
quantity available
based on enclosure
size selected)
Branch
Circuit
Breaker
Option
Feed
Type
Control
Equipment
Options
# of
WLBs
Link
Power
Supply
Example: ALPD8B20BL4-GFFBBB00
• 65 in (1651 mm) enclosure (8 DPMs)
• Breaker panel
• 120 V~ 20 A breakers
• 3 Ø 4 W
• (1) Four-circuit 0-10 V / Switching
• (2) Four-circuit Switching
• (3) Four-circuit Phase Adaptive
• (2) Open space for expansion