SDS
Reference Number : MSDS-200515-03
常州上扬光电有限公司
CHANGZHOU SOARING TECHNOLOGY CO., LTD
常州市新北区电子产业园新科路 25 号
Tel/ +86-519-6988-0988
Page 3 of 6
・ Inhalation :
Make the victim blow his/her nose, gargle. Seek medical attention if necessary.
・ Skin contact :
Remove contaminated clothes and shoes immediately. Wash the adhere or contact region with soap and
plenty of water immediately.
・ Eye contact :
Immediately flush eyes with water continuously for at least 15 minutes. Seek medical attention immediately.
A battery cell and internal cell materials of an opened battery cell
・ Ingestion :
Induce vomiting. When it is impossible or the feeling is not well after vomiting, seek medical attention.
SECTION 5 FIRE-FIGHTING MEASURE
GENERAL HAZARD
Cell is not flammable but internal organic material will burn if the cell is incinerated. Combustion products
include, but are not limited to hydrogen fluoride, carbon monoxide and carbon dioxide.
EXTINGUSHING MEDIA
Use extinguishing media suitable for the materials that are burning.
SPECIAL FIREFIGHTING INSTRUCTIONS
If possible, remove cell(s) from fire fighting area. If heated above 125°C, cell(s) can explode/vent.
FIREFIGHTING EQUIPMENT
Use NIOSH/MSHA approved full-face self-contained breathing apparatus (SCBA) with full protective gear.
SECTION 6 ACCIDENTAL RELEASE MEASURES
ON LAND
Place material into suitable containers and call local fire/police department.
IN WATER
If possible, remove from water and call local fire/police department.
SECTION 7 HANDLING AND STORAGE
Storage
:
Store in a cool, well-ventilated area. Do not expose to high temperature(45
℃).
Since short circuit can cause burn hazard or safety vent to open, do not store