Cut Sheet

3
Maximum
Description Capacity
1
Model #
ACCESSORIES
Receptacles
Receptacle
2
15A, 125V NTR-15-
20A, 125V NTR-20-
GFCI Receptacle
2
15A, 125V NTR-15-GFCI-
20A, 125V NTR-20-GFCI-
Note: The insert is permanently attached.
Isolated Ground Receptacle
2
15A, 125V NTR-15-IG-OR-
20A, 125V NTR-20-IG-OR-
Note: Receptacle is orange; wallplate is color selected.
Receptacles can be special ordered to match wallplate color;
consult Customer Service.
Duplex for Dimming Use
2
15A, 125V NTR-15-DFDU-
20A, 125V NTR-20-DFDU-
Note: The insert is permanently attached.
Half for Dimming Use
2
15A, 125V NTR-15-HFDU-
20A, 125V NTR-20-HFDU-
Note: The insert is permanently attached.
Replacement Plug for Dimming Use
10A, 125V RP-FDU-10-
Telephone and Cable Television Jacks
Cable TV Jack
2, 5
S
INGLE
F-
STYLE
NT-CJ-
75-Ohm, coaxial cable jack
Telephone Jack
5
S
INGLE
6-conductor, RJ11 NT-PJ-
Note: Also accepts most 4-conductor plugs.
D
OUBLE
8-conductor, RJ45, Category 5 NT-PJ8X2-
Note: Also accepts most 4- or 6-conductor plugs.
T
RIPLE
8-conductor, RJ45, Category 5 NT-PJ8X3-
Note: Also accepts most 4- or 6-conductor plugs.
Telephone/Cable Jack
2, 5
8-conductor, RJ45,
Category 5 phone jack-F-style,
75-Ohm, coaxial cable jack NT-PJ8CJ-
Note: Phone jack also accepts most 4- or 6- conductor plugs.
Wallplate and insert match specified color. Device (e.g., Jack)
and device trim are white for ivory, white and beige products;
black for gray, brown, black, metal, special metal and anodized
aluminum products.
Maximum
Description Capacity
1
Model #
HI-POWER 2•4•6
TM
DIMMING MODULES
To increase load capacity up to 30,000W/VA in most popular
sources, use one NT-600- or NT-603P- and add up to five
dimming modules. Cannot be used with 0-10VDC ballast.
LINEAR-SLIDE SWITCHES
General Purpose Switching
of All Sources and Motor Loads
Linear-Slide Switches
2
S
MALL
C
ONTROL
Single pole, 120/277V 20A NT-1PS-
3-way, 120/277V 20A NT-3PS-
4-way, 120/277V 20A NT-4PS-
Switching for Motorized Shades
Double pole, double throw switches for raise/lower/
center off applications
Linear-Slide Switches
2
S
MALL
C
ONTROL
Momentary 2HP NT-DPDT-CO-MO-
120/240VAC
Maintain 1/2HP@120VAC; NT-DPDT-CO-MA-
120/240VAC 2HP@240VAC
Note: To control more than one motor, consult Lutron Technical
Support.
FAN-SPEED CONTROLS
Quiet Controls
For use with one ceiling paddle fan.
Slide-to-Off Fan-Speed Control
2
S
MALL
C
ONTROL
Single pole, 3-speed 1.5A NTFSQ-
Fully Variable Controls
For use with one or more ceiling, ventilation, or exhaust fan.
Do not mix fan types on one control.
Slide-to-Off Fan-Speed Control
S
MALL
C
ONTROL
Single pole/Adjustable Minimum Speed
6A NTFS-6E-
L
ARGE
C
ONTROL
Single pole/Adjustable Minimum Speed
12A NTFS-12E-
1 For capacities in multigang installations see derating information.
2 No derating required if ganged.
3 Actual lamp wattage.
4 Requires neutral.
5 A physical barrier (partition) must exist when ganging with line-voltage products.
Have Questions? Call the Lutron Hotline 800-523-9466
To order—Call Lutron Customer Service 888-588-7661
Controls