Cut Sheet
Maximum
Description Capacity
1
Model #
DIMMERS
Magnetic Low Voltage,
Neon/Cold Cathode
Slide-to-Off Dimmers
S
MALL
C
ONTROL
Single pole 600 VA (450 W
2
) NLV-600-
L
ARGE
C
ONTROL
Single pole 1000 VA (800 W
2
) NLV-1000-
Single pole 1500 VA (1200 W
2
) NLV-1500-
Note: For neon/cold cathode dimming consult Lutron Technical
Support “Application Note #15”.
Preset Dimmers
S
MALL
C
ONTROL
Single pole/3-way 600 VA (450 W
2
) NLV-603P-
Single pole/3-way 1000 VA (800 W
2
) NLV-1003P-
L
ARGE
C
ONTROL
Single pole/3-way 1500 VA (1200 W
2
) NLV-1503P-
Single pole/3-way 2000 VA (1600 W
2
) NLV-2003P-
Fluorescent Dimming with Hi-lume® and
Eco-10TM (ECO-Series) Electronic Ballasts
Slide-to-Off Dimmers
3
S
MALL
C
ONTROL
Single pole, 120 V 16 A NF-10-
L
ARGE
C
ONTROL
Single pole, 277 V 8 A NF-10-277-
Note: Use with Lutron Hi-lume or Eco-10 (ECO-Series) line
voltage control Electronic Dimming Ballasts only.
Preset Dimmers
3
S
MALL
C
ONTROL
Single pole/3-way, 120 V 8 A NF-103P-
Single pole/3-way, 277 V 6 A NF-103P-277-
Note: Use with Lutron Hi-lume or Eco-10 (ECO-Series) line
voltage control Electronic Dimming Ballasts only.
1
For capacities in multigang installations see derating, page 4.
2
Actual lamp wattage.
3
No derating required if ganged.
Maximum
Description Capacity
1
Model #
DIMMERS
Fluorescent Dimming with Eco-10
(TVE-Series) 0-10V- Electronic Ballasts
Slide-to-Off Dimmers
3
S
MALL
C
ONTROL
Single pole, 0-10 V- 60 ballasts/16 A NFTV-
Use with PP-20 or PP-120H/277H
Note: Use with Lutron Eco-10 (TVE-Series) 0-10V- Electronic
Dimming Ballasts only. Requires use of an external relay to
switch ballast power on/off, Lutron model number PP-20 or
PP-120H/277H .
Fluorescent Dimming with Tu-WireTM
Electronic Ballasts
Slide-to-Off Dimmers
S
MALL
C
ONTROL
Single pole, 120 V 5 A NFTU-5A-
Note: Use with Lutron Tu-Wire line voltage control Electronic
Dimming Ballasts only.
Fluorescent Dimming with
Magnetic Ballasts
Slide-to-Off Dimmers
3
S
MALL
C
ONTROL
Single pole, 120 V 10 lamps NF-10-
L
ARGE
C
ONTROL
Single pole, 120 V 20 lamps NF-20-
Single pole, 120 V 30 lamps NF-30-
Single pole, 277 V 10 lamps NF-10-277-
Single pole, 277 V 20 lamps NF-20-277-
Note: Magnetic dimming ballasts generally cannot be effectively
dimmed below 20% low end. For best performance and relia-
bility, Lutron strongly recommends using Hi-lume or Eco-10
electronic dimming ballasts.
HI-POWER 2•4•6
TM
DIMMING MODULES
To increase load capacity up to 30,000 W/VA in most popular
sources, use one N-600- and add up to five dimming modules.
Cannot be used with 0-10 V- ballast.
Have Questions? Call the Lutron Hotline 800-523-9466
To order—Call Lutron Customer Service 888-588-7661
Controls
PP-20
2