Installation Guide
Single-gang
gangable wallbox
Four-gang
gangable wallbox
3/4" (19 mm) space
(use chase nipple)
3
Multigang Installation:
No Side Sections Removed,
No Derating Required
1.
Determine the number of large and small controls
required.
When ganging any combination of small and large controls,
place a small control on one extreme end of the gang, and a
large control at the other end of the gang. Use the chart
below to find your wallbox requirements.
Ganging and Special Wallplates
Dimmers can be ganged with the entire family of Nova controls.
FOR NEW CONSTRUCTION we suggest installing the dimmers
without breaking or removing the side sections. This will insure
that the control can be loaded to its full-rated capacity (no
derating). Follow the instructions below to install your controls with
NO SIDE SECTIONS REMOVED. For a retrofit installation, side
sections can be removed from the controls to fit existing
wallboxes; however, this will require load derating.
To maintain a smooth, clean installation, one-piece Lutron Multi-
Gang Wallplates are available. Custom finishes, engraving and
silkscreening are available upon request.
Note: NLV-603P, NLV-1003P are listed as “small” controls.
NLV-1503P, NLV-2003P are listed as “large” controls.
Note: When ganging an even number of small controls with no
side sections removed, do not use plaster rings or gangbox
covers. Space an additional wallbox 3/4" (19 mm) apart from the
other wallbox(es). A 3/4" (19 mm) close nipple is recommended
as a spacer between the wallboxes.
Note: Masonry Multi-Gang Wallboxes are recommended for
neater installations.
2. Assemble the controls.
Use the center or offset mounting holes as needed. Allow a
1/32" (0.8 mm) space between controls for ease in attaching
the wallplate.
Example: Four-Gang Controls
3. Snap on Multi-Gang Wallplate
Example: Four-Gang Wallplate
Multigang Installation:
Side Sections Removed,
Derating Required
1.
Determine the number of large and small controls
required.
When ganging any combination of small and large controls,
place all small controls on one end of the gang and all large
controls on the other. Use the chart below to determine the
size and maximum capacity of each control.
0123456
0 0 1 1+1 4 4+1 7 1+7
113568911
24679101213
36 8 1011131416
4 9 11 12 14 15 17 18
Wallbox Requirement Chart
Number of Small Controls
No Side
Sections
Removed
Number of
Large
Controls
0123456
00123456
11345678
235678910
35789101112
47 9 1011121314
Wallbox Requirement Chart
Number of Small Controls
All Inside
Sections
Removed
Number of
Large
Controls
NLV-603P S 600VA 600VA 500VA
NLV-1003P S 1000VA 900VA 700VA
NLV-1503P L 1500VA 1250VA 1000VA
NLV-2003P L 2000VA 1800VA 1500VA
Model
Control
Size
No Sides
Removed
1 Side
Removed
2 Sides
Removed
Capacity Derating Chart
2. Derating is necessary when side sections are removed.
Offset Mounting Hole
Center Mounting Hole