Cut Sheet
Table Of Contents
®
SPECIFICATION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
Dual Technology Occupancy Sensor Switch
369773c 13 04.09.14
Maestro® Sensor
How Loads Operate in 3-Way with Dual-Circuit Sensor Switch (MS-B202)
Initial Load State After flipping 3-way mechanical switch
Circuit 1 Circuit 2 Circuit 1 Circuit 2
When All Lights are OFF Off Off On On
When All Lights are ON On On Off Off
When One Circuit is ON
On Off Off Off
Off On Off Off
3-Way Installation
For retrofit 3-way installations the mechanical switch needs to be rewired as shown in the diagram below after wiring the
Dual Tech Sensor Switch. Otherwise the 3-way installation will not work as expected. Single-Pole mechanical switches may
also be used in a 3-way with MS-B102, MS-B102-V and MS-B202 models.
m30
15
5
1
Occ
LRN
Fixd
Vac
Mode
Hi
Med
Low
Off
Hi
Med
Low
Min
PIR
m30
15
5
1
Hi
Med
Low
Off
Occ
Lrn
Fixd
Vac
Mode
Hi
Med
Low
Min
PIR
Traditional 3-Way Mechanical Switch Wiring
Ground
Traveler Traveler
Common
1. Connect Ground: Ensure the bare copper or green ground wire from the wallbox is connected to the green ground screw of
the mechanical switch.
2. Tag circuit Common: Your 3-way mechanical switch should have three screw terminals, two of the same color, and one of a
different color. Tag the wire that is connected to the screw terminal of a different color.
3. Identify the wire that matches the color of the wire you connected to the blue wire of the Maestro
R Dual Technology
Occupancy Sensor Switch. Connect this wire to one of the two terminals of the same color.
4. Combine the tagged wire, the remaining wire and yellow jumper wire (included) using a wire connector. Connect the other end
of jumper wire to the different color screw.
m30
15
5
1
Occ
LRN
Fixd
Vac
Mode
Hi
Med
Low
Off
Hi
Med
Low
Min
PIR
m30
15
5
1
Hi
Med
Low
Off
Occ
Lrn
Fixd
Vac
Mode
Hi
Med
Low
Min
PIR
Yellow Jumper
wire (included)
Traveler (to Blue wire)
Tagged Wire
(Common)
Traveler
(to Black OR Black-Orange wire)
Ground
Different
color
screw
3-Way Mechanical Switch Wiring with Dual Tech Sensor Switch
Different
color
screw
Rewire to
13