Cut Sheet

Job Name:
Job Number:
Model Numbers:
PageSPECIFICATION SUBMITTAL
369-143 L 6 03.01.12
RF Local ControlsMaestro WirelessR Designer-style: Maestro
R
Specifications
Regulatory Approvals
UL Listed.
CSA Certified.
FCC Approved. Complies with the limits for a
Class B digital device, pursuant to Part 15 of the
FCC Rules.
Industry Canada Certified.
Power
Operating voltage:
120 V~ 50/60 Hz
277 V~ 50/60 Hz (MRF2-6ANS-277,
MRF2-8S-DV, MRF2-F6AN-DV)
Key Design Features
Dimmers
On a single-tap, lights fade UP or DOWN.
On a double-tap, lights go to full ON.
When ON, press and hold to engage 20-second
fade to OFF.
Light levels can be fine-tuned by pressing and hold-
ing the dimming rocker until the desired light level is
reached.
Two-wire dimmers available.
Switch
On a single-tap, lights turn ON or OFF.
Two-wire switches available.
All RF Local Controls
Tested to withstand electrostatic discharge without
damage or memory loss, in accordance with IEC
61000-4-2.
Tested to withstand surge voltages without dam-
age or loss of operation, in accordance with IEEE
C62.41-1991 Recommended Practice on Surge
Voltages in Low-Voltage AC Power Circuits.
Controls always operate locally and do not require
system control.
Power failure memory: should power be
interrupted, the control will return to its previously
set level prior to the interruption when power is
restored.
Uses conventional 3-way and 4-way wiring.
Multiple location control from Dimmer/Switch and
up to 9 Companion Dimmer(s) / Switch(es).
Use LutronR Designer (ClaroR
and Satin ColorsR)
wallplates or designer-style wallplates from other
manufacturers. Wallplates are sold separately.
Lutron ClaroR and Satin ColorsR wallplates snap
on with no visible means of attachment.
Requires a 1-gang U.S. wallbox. 3
1
2 in (89 mm)
deep recommended, 2
1
4 in (57 mm) deep
minimum.
Green indicator lights.
System Communications
and Capacity
Maestro WirelessR controls communicate with the
PicoR wireless controls and Radio Power SavrT
sensors through radio frequency (RF).
Maestro WirelessR local controls must be located
within 60 ft (18 m) line of sight or 30 ft (9 m)
through walls, of Radio Power SavrT sensors.
Maestro WirelessR local controls must be located
within 100 ft (30 m) line of sight or 30 ft (9 m)
through walls, of a PicoR wireless control.
Up to 10 Maestro WirelessR controls can be
configured to work together.
Environment
Ambient operating temperature: 32 °F to 104 °F
(0 °C to 40 °C), 0%-90% humidity,
non-condensing. Indoor use only.
6