Cut Sheet
Job Name:
Job Number:
Model Numbers:
PageSPECIFICATION SUBMITTAL
369-143 L 13 03.01.12
RF Local ControlsMaestro WirelessR Designer-style: Maestro
R
Multi-Location Installation with Power Booster
2,3
Single Feed
MRF2-F6AN-DV with MA-R / MSC-AD and PHPM-3F-DV-WH,
PHPM-PA-DV-WH, or PHPM-WBX-DV-WH
Multi-Location Installation with Power Booster
2,3
Dual Feed
MRF2-F6AN-DV with MA-R / MSC-AD and PHPM-3F-DV-WH,
PHPM-PA-DV-WH, or PHPM-WBX-DV-WH
DH
DH
Load
Load
Brass
Brass
Black
Black
Blue
Blue
Green
Green
Green
Green
Ground
Ground
Ground
Ground
Ground
Ground
Hot/Live
Hot/Live
Hot/Live
Neutral
Neutral
Companion
Dimmer
Companion
Dimmer
Dimmer
Dimmer
Single Location Installation with Power Booster
Single Feed
MRF2-F6AN-DV with PHPM-3F-DV-WH, PHPM-PA-DV-WH,
or PHPM-WBX-DV-WH
Single Location Installation with Power Booster
Dual Feed
MRF2-F6AN-DV with PHPM-3F-DV-WH, PHPM-PA-DV-WH,
or PHPM-WBX-DV-WH
DH
DH
Dimmer Dimmer
120 V~
60 Hz
120 V~
60 Hz
120 V~
60 Hz
or
277 V~
60 Hz
120 V~
60 Hz
or
277 V~
60 Hz
120 V~
60 Hz
120 V~
60 Hz
Brass - unused, tighten
4
Brass - unused, tighten
4
Brass -
unused,
tighten
4
Brass -
unused,
tighten
4
Silver
Silver
Silver
Silver
Black
Black
Black
Black
Green
Orange wire
Orange wire
Orange wire
Orange wire
Green
Ground
Ground
Hot/Live
Hot/Live
Hot/Live Hot/Live
Hot/Live
Dimmed Hot
Dimmed Hot
Dimmed Hot
Dimmed Hot
Neutral
Neutral
Neutral
Neutral
Neutral
Neutral
Zone In
Zone In
Zone In
Zone In
Neutral
Neutral
Neutral
Neutral
Neutral
Neutral
Load
Load
1
When using controls in single location installations, tighten the blue terminal. DO NOT connect the blue terminal to any other wiring or to ground.
2
Up to 9 MaestroR Companion Dimmers may be connected to the Maestro WirelessR Dimmer. Total blue terminal wire length may be up to 250 ft (76 m).
3
Neutral wire Dimmers must be connected on the Load side of a multi-location installation.
4
When using a PHPM, tighten the brass (Sw Hot) terminal of the MRF2-F6AN-DV. DO NOT connect the brass terminal to any other wiring or to ground.
Wiring Diagrams
Blue - unused, tighten
1
Blue - unused, tighten
1
Ground
Ground
13