Cut Sheet
®
SPECIFICATION SUBMITTAL Page
Job Name:
Job Number:
Model Numbers:
Radio Powr SavrT Wireless Wall-Mount Occupancy and Vacancy Sensors
369481d 6 04.01.13
Coverage Diagrams
Hallway Sensors
(Models:LRFX-OHLB-P-WHandLRFX-VHLB-P-WH)
•Designedtomountattheendofahallwaywithaclearviewdownthelengthofahall.
•Detectionatlongerdistancesisbestwhenmotionoccursatrightanglestothesensor.
•Multiple sensors can be used to extend coverage.
*Sensormountingshownat7ft(2.1m).Mountingheightshouldbebetween6ftand8ft(1.8mand2.4m)andcenteredwithinhallway.
Width of Hall Length of Hall
6 ft (1.8 m) or less 50 ft (15.2 m)
8 ft (2.4 m) 100 ft (30.5 m)
10 ft (3.0 m) or more 150 ft (45.7 m)
Maximum Recommended Hallway Length
5ft
(1.5m)
0ft
(0m)
5ft
(1.5m)
0ft
(0m)
25ft
(7.6m)
50ft
(15.2m)
75ft
(22.9m)
100ft
(30.5m)
150ft
(45.7m)
125ft
(38.1m)
0ft
(0m)
25ft
(7.6m)
50ft
(15.2m)
75ft
(22.9m)
100ft
(30.5m)
150ft
(45.7m)
125ft
(38.1m)
0ft
(0m)
7ft
(2.1m)
Top View
Side View
6