Cut Sheet

product specifications
10.27.15369547d
Remote Power Modules
3www.lutron.com Technical support: U.S.A.: 800.523.9466
Europe: +44.(0)20.7680.4481
Load Type, Rating, and Capacity
Model
Voltage/
Frequency
Load Types
1
Minimum
Load
Maximum Load Per:
Maximum
BTUs / Hour
Technology
Output Module
HW-RPM-4A-120
120 V~
50/60 Hz
INC, MLV, ELV,
NCC, F2W
10 W 10 A 16 A
90 RTISS-TE
TM
6
LED
2
See note
2
HW-RPM-4A-230
220–240 V~
50/60 Hz
INC, MLV, ELV,
NCC
10 W 8 A 13 A
LED
2
See note
2
HW-RPM-4E-230-CE
220–240 V~
50/60 Hz
INC, ELV
3
10 W 10 A 16 A
HW-RPM-4J-120
120 V~
50/60 Hz
INC, MLV, ELV,
NCC, F2W
10 W 6 A 16 A
LED
2
See note
2
HW-RPM-4FSQ-120
120 V~
50/60 Hz
Fan Motor
4
0.25 A 2 A 8 A
18
Quiet control
circuitry
HW-RPM-4M-120
120 V~
50/60 Hz
INC 0 A 3 A
16 A
Mechanical
interlocked
relays
Motor
(Bi-directional)
5 A (1/4 HP)
HW-RPM-4M-230
220–240 V~
50/60 Hz
INC 0 A 1.5 A
16 A
Motor
(Bi-directional)
5 A (1/4 HP)
HW-RPM-4R
100–277 V~
50/60 Hz
Lighting 0 A 16 A
64 A Softswitch
®
7
Motor (1/3 HP)
HW-RPM-4U-120
120 V~
50/60 Hz
INC
5
, MLV
5
,
NCC, F2W, SFL
25 W 16 A 16 A
70
RTISS
Equipped
®
8
LED
2
See note
2
HW-RPM-4U-230-CE
220–240 V~
50/60 Hz
INC, MLV,
NCC, SFL
40 W 10 A 13 A
LED
2
See note
2
HW-RPM-4U-240
220–240 V~
50/60 Hz
INC, MLV,
NCC,SFL
40 W 16 A 16 A
LED
2
See note
2
1
For higher wattages or for load types other than those listed, a power booster or interface is required. For more details, refer to the
HomeWorks
® software.
2
NOTICE: To avoid the risk of equipment damage and for specific LED lamp / fixture compatibility, refer to the LED Product Selection
tool at www.lutron.com/ledtool. For general information about minimum/maximum load requirements and LED loads refer to
Application Note #487 - Minimum and Maximum loads for LED and CFL lamps / fixtures. Please note that LED is not currently a
supported load type of UL
® 508. As a result, this UL® listing does not guarantee compatibility between the remote power module and
connected LED loads.
3
Only use with ELV transformers. If used with MLV transformers, the module may be damaged and the warranty will be void.
4
Control up to 4 ceiling fans (1 per circuit). Do not use to control fans that have integrated fan speed controls (i.e., fan with a remote control).
This module may hum or buzz when at medium-high fan setting. Do not connect to lighting loads. Damage to the module could result.
5
In rare cases, incandescent lamps and MLV transformers will “buzz” or “hum”. The HW-HIFC-10-2 filter choke assembly reduces this hum.
The filter choke assembly can be installed in place of module 8 in an HWI-PNL-8 remote power panel.
6
RTISS-TETM: (Real-Time Illumination Stability System-Trailing Edge). Same as RTISS®, but operates on the trailing edge of the A/C sine wave.
This allows for true instantaneous voltage compensation.
7
Softswitch®: Lutron® Softswitch® circuitry prevents the relay contacts from arcing. Even when fully loaded, the arc reduction extends a relay’s
average rated life to more than 1,000,000 on/off cycles.
8
RTISS Equipped® (Real-Time Illumination Stability System). This Lutron® filter circuit technology compensates for incoming line-voltage
variations, such as changes in Root Mean Square (RMS) voltage, frequency shifts, harmonics, and line noise.