Load Type and Capacity
1
The RR-3PD-1 is designed to dim one incandescent, magnetic low-voltage, or tungsten halogen table or floor lamp. The RR-3PD-1
can be configured to switch a CFL, fluorescent, or electronic low-voltage load. Use with lighting loads only. Do not use to control a lamp
that contains an integral dimmer or a touch lamp. For a lamp with an integral 3-way switch, the switch should be set to full on position.
The RR-3PD-1 may not work with dioded light bulbs. Always use a load that complies with the Load Type and Capacity table above.
Always use a light bulb that remains within the wattage rating of the light fixture.
2
Low-Voltage Applications: The RR-3PD-1 can be used with magnetic (core and coil) low-voltage transformers in both dimming and
switching modes. Use with electronic (solid-state) low-voltage transformers in switching mode only. Operation of a low-voltage circuit with
light bulbs inoperative or removed may result in transformer overheating and premature failure. Lutron strongly recommends the following:
a. Do not operate low-voltage circuits without operative light bulbs in place.
b. Replace burned-out light bulbs as soon as possible.
c. Use transformers that incorporate thermal protection or fused transformer primary windings to prevent transformer failure due to
overcurrent.
3
The RR-15APS-1 is designed to switch general purpose loads (lighting, non-lighting, motor-operated, or transformer supplied
appliances). Total connected load can not exceed 1/2 HP, or 15 A. Peak horsepower is not reflective of the UL appliance horsepower
rating. Consult appliance manufacturer for UL horsepower rating.
4
Some low wattage loads may try to start when the Appliance Module is OFF due to 0.5 mA leakage current through the module, similar
to a night lighted toggle switch. Consult the load manufacturer for compatibility.
Control Load Type Min.
Load
Max.
Load
3PD-1
1
Incandescent, Halogen 10 W 300 W
MLV
2
10
W / VA
200 W /
300 VA
CFL, Fluorescent, ELV (Switching Mode Only) 10 W 300 W
15APS-1
3
General purpose None
4
1/2 HP
15 A
I
H
RadioRA 2 RF Plug-In Modules
Installation
Plug the load cord into a Plug-In Module
receptacle.
Insert the plug of the Plug-In Module into the
wall outlet.
NOTE: The Plug-In Dimming Module contains a POLARIZED cord set. It has a polarized plug
(one blade is wider than the other) and outlet (one slot is wider than the other). The polarized plug is
not intended to be mated with non-polarized outlets (having both slots the same size). The polarized
outlet is intended to mate with a polarized plug in only one way (the longer slot with the wider blade).
Plug-In Module
Plug-In Module Receptacle
Plug-In Module Plug
Load Cord
Wall Outlet