Instructions / Assembly
Single-Gang
Total CFL/LED
Wattage Installed
Maximum Allowable
Incandescent/Halogen
Wattage
0 W + 600 W
1-25 W + 500 W
26-50 W + 400 W
51-75 W + 300 W
76-100 W + 200 W
101-125 W + 100 W
126-150 W + 0 W
2-Gang
Total CFL/LED
Wattage Installed
Maximum Allowable
Incandescent/Halogen
Wattage
0 W + 500 W
1-25 W + 400 W
26-50 W + 300 W
51-75 W + 200 W
76-100 W + 100 W
101-125 W + 50 W
126-150 W + 0 W
3-Gang
Total CFL/LED
Wattage Installed
Maximum Allowable
Incandescent/Halogen
Wattage
0 W + 400 W
1-25 W + 300 W
26-50 W + 200 W
51-75 W + 100 W
76-100 W + 50 W
101-125 W + 0 W
126-150 W + 0 W
www.lutron.com © 9/2010
Technical Support Center
1.800.523.9466
Customer Service 1.888.LUTRON1
Example 1:
1. I have a single-gang dimmer and 3 CFL
bulbs that are 16 W each, totaling 48 W.
2. Because I have 48 W of CFL bulbs
installed, I can have up to 400 W of
incandescent bulbs also controlled by
this dimmer (6 incandescent bulbs that
are 65 W each = 390 W)
(Please note this example applies to a single-gang dimmer only)
How to calculate wattage when mixing lamp types: (example only)