Installation Guide
Black
Light
Red
Red
Ground
Dimmer
3-Way Switch
120 V
60 Hz
Green or Bare
Lutron Electronics Co., Inc.
7200 Suter Road
Coopersburg, PA 18036-1299, U.S.A.
P/N 0301689 Rev. A
ON
OFF
ON
OFF
ON
OFF
SINGLE-POLE:
Insulated wires connected 
to two screws of the 
same color. Replace with 
a SINGLE-POLE dimmer. 
See Step 5a.
OR
3-WAY:
Insulated wires connected to three screws. One of 
these wires is connected to a screw of a different-
color (not green) or labeled COMMON. MARK or 
TAG this wire to identify it when wiring. Replace 
with a 3-WAY dimmer. See Step 5b.
Tag
Different-colored screw 
(Common). Actual location may 
vary.
OR
Ground (Bare 
Copper or 
Green Wire)
Ground (Bare Copper 
or Green Wire)
ON
OFF
ON
OFF
ON
OFF
  Important Notes Please read before installing.
1. CAUTION: Use only with permanently-installed 120 V~ 
incandescent or halogen xtures. To avoid overheating and 
possible damage to other equipment, do not use to control 
receptacles, uorescent lighting xtures, motor-driven appliances, 
or transformer-supplied appliances.
2.  Install in accordance with all national and local electrical codes.
3.  Only one dimmer can be used in a 3-way circuit.
4.  When no “grounding means” exist within the wallbox then 
NEC
® 2008, Article 404.9 allows a dimmer without a grounding 
connection to be installed as a replacement, as long as a plastic, 
noncombustible wallplate is used. For this type of installation, 
cap or remove the green ground wire on the dimmer and use an 
appropriate wallplate such as Lutron's Claro
® or Fassada® series 
wallplates.
5.  For new installations, install a test switch before installing the 
dimmer.
6.  Protect dimmer from dust and dirt when painting or spackling.
7.  Recommended minimum load is 40 W.
8.  It is normal for the dimmer to feel warm to the touch during 
operation.
9.  Clean dimmer with a soft damp cloth only. Do not use any 
chemical cleaners.
Limited Warranty
Lutron will, at its option, repair or replace any unit that is defective in materials or manufacture within one year after purchase. For warranty service, return unit to place 
of purchase or mail to Lutron at 7200 Suter Rd., Coopersburg, PA 18036-1299, postage pre-paid.
THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES, AND THE IMPLIED WARRANTY OF MERCHANTABILITY IS LIMITED TO ONE YEAR FROM 
PURCHASE. THIS WARRANTY DOES NOT COVER THE COST OF INSTALLATION, REMOVAL OR REINSTALLATION, OR DAMAGE RESULTING FROM MISUSE, ABUSE, 
OR DAMAGE FROM IMPROPER WIRING OR INSTALLATION. THIS WARRANTY DOES NOT COVER INCIDENTAL OR CONSEQUENTIAL DAMAGES. LUTRON’S LIABILITY 
ON ANY CLAIM FOR DAMAGES ARISING OUT OF OR IN CONNECTION WITH THE MANUFACTURE, SALE, INSTALLATION, DELIVERY, OR USE OF THE UNIT SHALL 
NEVER EXCEED THE PURCHASE PRICE OF THE UNIT. 
This warranty gives you specific legal rights, and you may have other rights which vary from state to state. Some states do not allow the exclusion or limitation of 
incidental or consequential damages, or limitation on how long an implied warranty may last, so the above limitations may not apply to you.
NEC is a registered trademark of the National Fire Protection Association, Quincy, Massachusetts. Lutron, Claro, Fassada, and Glyder are registered trademarks of Lutron 
Electronics Co., Inc. © 2013 Lutron Electronics Co., Inc.
Technical Assistance
If you have questions concerning the installation or operation of this product, call the
Lutron Technical Support Center. Please provide exact model number when calling.
U.S.A. and Canada (24 hrs/7days) 
+1.800.523.9466
México  
+1.888.235.2910
Other countries 8am – 8pm ET 
+1.610.282.3800
Fax +1.610.282.6311
http://www.lutron.com
?
Installation
1
  Turning OFF Power.
• Turn power OFF at circuit breaker (or remove fuse).
2
  Removing Wallplate and Switch.
• Remove wallplate and switch mounting screws. 
• Carefully remove switch from wall (do not remove wires).
Caution: Verify 
power is OFF to 
switch before 
proceeding.
3
Identifying the Type of Circuit.
7
  Turning ON Power.
• Turn power ON at circuit breaker 
(or replace fuse).
6
  Mount Dimmer to Wallbox.
• Form wires carefully into the wallbox, 
mount and align dimmer.
• Install wallplate.
• NOTE: Only one dimmer can be 
used in a 3-WAY circuit.
• Connect the green or bare 
dimmer ground wire to the green 
or bare copper ground wire in the 
wallbox. (See Important Note 4.)
• Connect the black dimmer wire 
to the wire removed from the 
different-colored screw on the 
switch (marked or tagged wire).
• Connect one of the red dimmer 
wires to either of the remaining 
wires removed from the switch.
• Connect the remaining red 
dimmer wire to the remaining wire 
removed from the switch.
• Connect the green or bare dimmer 
ground wire to the green or bare 
copper ground wire in the wallbox. 
(See Important Note 4.)
• Connect one of the black dimmer 
wires to either of the wires 
removed from the switch.
• Connect the remaining black 
dimmer wire to the other wire 
removed from the switch.
  Note: To use a 3-Way dimmer 
(one black and two red wires) 
in a single-pole application, cap 
off one of the red wires and 
follow instructions for single-pole 
wiring. (If the on/off switch works 
backwards, switch the red wires.)
5
  Wiring the Dimmer.
• For installations involving more than one control in a wallbox, 
refer to the section on Multigang Installations before beginning.
 5a - Single-Pole Wiring
 5b - 3-Way Wiring
Ground
Red
Black
Tag
  Dimmer Rating  No sides removed  1 side removed  2 sides removed
  600 W  600 W  500 W  400 W
  1000 W  1000 W  800 W  650 W
Dimmer Capacity Chart
English
Start screws.
Align dimmer and 
tighten screws.
Note: To install a 
traditional style 
wallplate, rmly pull 
the Glyder® or Rotary 
knob to remove it. 
Install the wallplate 
and re-attach the knob.
Glyder®
Rotary
Multigang Installations
When installing more than one control in the same wallbox, 
it may be necessary to remove all inner side sections prior 
to wiring (see diagram). If pre-installed, remove the Lutron 
wallplate and wallplate adapter from dimmer. Using pliers, 
bend side section up and down until they break off. Repeat 
for each side section to be removed. Removal of dimmer 
side sections reduces maximum load capacity. Refer to chart 
below for maximum dimmer capacity.
Do Not Remove 
Outside Sections
Each Control Has Inside 
Sections Removed
Middle Control Has Two Side 
Sections Removed
Incandescent / 
Halogen
120 V~ Dimmer
Rated at 120 V~ 60 Hz
Lutron Technical Support Center 1.800.523.9466 24 hrs / 7 days www.lutron.com
4
Disconnecting Switch Wires.
One wire in the 
backwired hole 
and one to the 
screw.
One continuous 
wire to the 
screw.
Screw Terminals:
Turn screws to loosen.
Push-in Terminals:
Insert screwdriver. Pull 
wire out.
Looped Wire:
Turn screw to loosen.
Important Note: Your wall switch may have two wires attached to the same 
screw (see illustrations below for examples). Tape these two wires together before 
disconnecting. If your switch has two wires attached to the same terminal, connect 
both wires to the Dimmer terminal in Step 5.
• Easy-to-follow Instructions
• Instrucciones Fáciles de Seguir
P/N 0301689
• Easy-to-follow Instructions
• Instrucciones Fáciles de Seguir
P/N 0301689
Models:
600 W
D-600P
D-600R
D-603P
DNG-600P
DNG-603P
DV-600P
DV-603P
DVSC-600P
1000 W
AY-10P
AY-10PNL
AY-103P
AY-103PNL
DV-10P 
DV-103P 
DVSC-10P 
DVSC-103P 
DVSC-603P
DVW-600P
DVW-603P
GL-600
GL-600P
GL-603P
LT-600
LT-603P
DW-10P 
DW-103P 
GL-10P
GL-1000
GL-103P
LT-103P
S-10P
S-10PNL
S-600
S-600P
S-600PNL
S-603P
S-603PNL
SW-600
SW-600P
SW-603P
S-1000
S-103P
S-103PNL
TG-10P
TG-10PNL
TG-103P
Black Black
Green or Bare
Ground
Light
120 V
60 Hz
WARNING: Shock Hazard. May result in serious 
injury or death. Turn off power at circuit 
breaker before installing the unit.
Dimmer wire location may vary by model number.
Reference wires by color, not backcover location.
NOTE:
Green 
or Bare
Green or Bare
Ground
Black