Installation Guide

Installation
* Ketra’s lighting products should only be controlled via our digital control architecture. Please refer to our controls products installation guides for
more information.
Fixture Placement
For ideal KetraNet Mesh wireless performance, position the Lamp according to these guidelines:
Keep within range: Place the Lamp within 50 ft (15.24 m) of at least one or more KetraNet Mesh
enabled device in its network.
Avoid obstructions: Avoid having metal obstructions or walls between the Lamp and the
nearest device.
Avoid metal enclosures.
Separate from Wi-Fi devices: Maintain at least 6 ft (1.8 m) of spacing between any KetraNet Mesh
product and Wi-Fi routers and access points.
Note: Ketra lighting products should not be connected to, or directly controlled by, AC mains
line voltage dimmers.* Ketra’s lighting products should only be controlled via our digital control
architecture. Please refer to our controls products installation guides for more information.
Power
The S30, S38, and A20 all require 120 V
60 Hz.
NODE NODENODE
50 nodes max per N4
50 FT MAX 50 FT MAX
6|LAMP INSTALLATION GUIDE
770-0000XX-01 r11
© 2019 Ketra, Inc. All rights reserved