Frequently Asked Questions

Table Of Contents
ON
5
Turn power ON at circuit breaker
4
Mount all devices using the provided screws
A
B
Hold
L
until bottom indicator light
is reached.
Tap
R
until all bulbs in the room are
on and stable (no flickering).
Single tap
T
to save setting.
Single tap
T
to turn off bulbs.
Single tap
T
again.
If all bulbs do not turn on or are not
stable, repeat step A, and in step B
increase light with
R
.
If your bulbs are flickering, buzzing or dropping out, your bulbs may not be compatible.
Please visit www.lutron.com/ledfinder to check the Compatible Bulb List.
Hold
T
&
L
until an indicator light
blinks on the dimmer.
Adjust Low-End Trim
Control Set-up
FASS
Pull tab out for bulb replacement.
DIMMER
Raise lights
Tap to toggle lights
on / off.
Double-tap to turn
lights on to full
intensity.
Press & hold for
delayed fade-to-off.
Lower lights
T
R
L
Displays the current light level
Indicator Lights
Control Operation
This control can be used in a RadioRA 2 or RA2 Select system for control from
keypads, Pico wireless controls, schedules, and more.
For RadioRA 2, use the system programming software to set up the system
(training required to access the software).
For RA2 Select, download the Lutron App from the App Store or Google Play
Store, open the App and follow the instructions to setup the system.
System Setup
NOTE: Resetting a device to its factory settings will remove it from the system
and erase all of its programming.
Step 1: Triple tap
T
.
Step 2: Press and hold
T
. Continue to hold
T
for approximately
3 seconds.
Step 3: Triple tap
T
. Load (light) will turn OFF and turn back ON to full intensity.
This indicates a successful factory reset.
Return to Factory Settings
Troubleshooting Guide
Phase-Select Mode
Symptoms Cause and Action
LEDs do not operate well or they
flicker/buzz.
Is the load from the Lutron compatible lamp tool? Please visit www.lutron.com/lednder
Adjust low-end trim
Connect Neutral wire
See Phase Select Mode
ILs 1 and 7 are flashing.
Over Voltage Protection
Verify that the control is set correctly for the load. • Check Phase-Select Mode setting.
Bottom three ILs 1, 2, and 3 are flashing. Shorted FET Detection
Wiring error. Product may be permanently damaged.
Check wiring to be sure it matches installation instructions and wiring diagrams.
All ILs are flashing. Over Current Protection Mode
Check Phase-Select Mode setting.
Verify that no bulbs are blown out.
Verify that product is wired properly.
Cycle power to the unit using the FASS switch to reset.
• If using LED or CFL bulbs, verify that they are Lutron compatible bulbs, please visit www.lutron.com/ledfinder
Load is OFF and there is no indicator on
the dimmer.
Power Not Present
Circuit breaker OFF or tripped. Verify that product is wired properly.
Load is not installed or connected. Dimmer must have a load to operate.
FASS is in the OFF position. Move FASS to the ON position by pushing it in.
Wiring Error
Check wiring to be sure it matches installation instructions and wiring diagrams.
Light turns ON and OFF continuously. Improper load type or less than the required minimum load
Recommended minimum load is 10 W / 10 VA or one compatible LED lamp listed at www.lutron.com/lednder. • Connect Neutral wire.
Middle IL is flashing. Over Temperature Condition
Load may exceed maximum load rating.
Ambient temperature may exceed maximum product rating.
Cycle power to the unit using the FASS switch to reset.
Dimmer IL is ON but load cannot be turned
ON and/or cannot be turned OFF.
Wiring Error
Check wiring to be sure it matches installation instructions and wiring diagrams.
Lamps Burned Out or Not Installed
Replace or install lamps.
ILs 3 and 7 are flashing. Line / Load Miswire Detected
Swap wires on Black and Brass screw terminals.
For additional Troubleshooting, please visit www.lutron.com/support
Note: For Advanced Programming Features please visit:
www.lutron.com/TechnicalDocumentLibrary/048703.pdf
1. Open the FASS.
2. Press and hold . Close the FASS
and continue to hold for 5 seconds.
Note: The current phase selection
will illuminate:
IL7 Forward-phase
IL4 Phase auto-select – Default with
no neutral*
IL1 Reverse-phase – Default with neutral
3. Press the / button to get to
the desired selection.
4. Press
T
to exit Phase-Select mode.
F
A
S
S
F
A
S
S
F
A
S
S
F
A
S
S
F
A
S
S
F
A
S
S
IL4
FWD
AUTO
REV
IL7
T
* LED phase auto-select defaults to reverse-phase unless the LED load cannot
operate correctly. It will then switch to forward-phase automatically. LED phase
auto-select is only available when no neutral wire is connected.
IL1
3 sec
TT