User's Manual
TouchPRO Wireless
™
P/N 041-338 Rev. A 9 69-2655EFS—01
Setup functions Settings & Options (factory default in bold)
Installer setup
Continuedonnextpage
0360 HP Aux Lockout 40 40 ºF 4.5 ºC
0 None
5 5ºF -15.0ºC
10 10 ºF -12.0 ºC
15 15ºF -9.5ºC
20 20ºF -6.5ºC
25 25ºF -4.0ºC
30 30 ºF -1.0 ºC
35 35ºF 1.5ºC
45 45ºF 7.0ºC
50 50ºF 10.0ºC
55 55ºF 13.0ºC
60 60ºF 15.5ºC
65 65ºF 18.5ºC
0500 Furnace Filter 1
Change Reminder
0 Disabled
1 10 R.T. Day
2 30 R.T. Day
3 60R.T.Day
4 90 R.T. Day
5 120R.T.Day
6 180R.T.Day
7 270R.T.Day
8 365R.T.Day
9 30 C Days
10 60CDays
11 90 C Days
12 120 C Days
13 180 C Days
14 365CDays
0502 Furnace filter
reminder run time
equipment counts
0 Counts heat and cool
1 Counts cool only
0510 Humidifier Pad
Replacement
Reminder
0 Disabled
1 90CDays,30R.T.Days
2 180CDays,60R.T.Days
3 365CDays,90R.T.Days
0520 UV Lamp
Replacement
Reminder
0 Disabled
1 365Days
2 730Days(2years)
0580 Compressor
protection
5 5 minute compressor OFF time
[Otheroptions:0,1,2,3or4-minuteofftime]
0640 Clock format 12 12-hour time (i.e., “3:30 pm”)
24 24-hourtime(i.e.,“15:30”)
0650 Extended fan
timer (heat)
0 OFF
90 Fan runs for 90 seconds after call for heat ends
0660 Extended fan
timer (cool)
0 OFF
90 Fan runs for 90 seconds after call for cooling ends
0670 Keypad lock 0 Keypad unlocked (fully functional)
1 Partially locked (access to temperature settings only)
2 Fully locked