User's Manual
Installation Guide
P/N 041-338 Rev. A 8 69-2655EFS—01
Setup functions Settings & Options (factory default in bold)
Installer setup
Continuedonnextpage
0300 Manual/Auto
changeover
1 Automatic changeover (Heat/Cool/Auto/OFF)
0 Manual changeover (Heat/Cool/OFF)
0320 Temperature
display
0 Fahrenheit ( ºF)
1 Celsius ( ºC)
0340 Remote Temperature
Sensor
0 None
1 Outdoor for Display
2 Outdoor for Control
3 Remote Indoor
0345 Dual Fuel Heat Pump
Control
0 Balancepointonly
1 Balance point + Failed to Maintain Heat protection
2 Lowlockout+HighLockout+FailedtoMaintain
protection in between.
0346 Dual Fuel Heat Pump
Upstage to Furnace
Timer
0 Disabled
0.5 0.5hours
1 1 hour
1.5 1.5hours
2 2 hours
3 3 hours
4 4 hours
5 5hours
6 6hours
8 8 hours
10 10 hours
12 12 hours
14 14 hours
16 16hours
0347 Drop Temperature 2 2 ºF 1.0 ºC
3 3ºF 1.5ºC
4 4 ºF 2.0 ºC
5 5ºF 2.5ºC
0350 HP Compressor
Lockout also Balance
Point
40 40 ºF 4.5 ºC
0 None
5 5ºF -15.0ºC
10 10 ºF -12.0 ºC
15 15ºF -9.5ºC
20 20ºF -6.5ºC
25 25ºF -4.0ºC
30 30 ºF -1.0 ºC
35 35ºF 1.5ºC
45 45ºF 7.0ºC
50 50ºF 10.0ºC
55 55ºF 13.0ºC
60 60ºF 15.5ºC