User's Manual
Installation Guide
P/N 041-338 Rev. A 10 69-2655EFS—01
Setup functions Settings & Options (factory default in bold)
Installer setup
0680 Heat temperature
control
2 Standard temperature control (recommended)
1 Choose if room is warmer than set temperature
3 Choose if room does not reach set temperature
0690 Cool temperature
control
2 Standard temperature control (recommended)
1 Choose if room is cooler than set temperature
3 Choose if room does not reach set temperature
0700 Temperature
display offset
0 Thermostat displays actual room temperature
[Otheroptions:-3ºF,-2ºF,-1ºF,1ºF,2ºF,3ºFoffset
(-1.5ºC,-1.0ºC,-0.5ºC,0.5ºC,1.0ºC,1.5ºC)]
0710 Reset 0 No reset
1 ResetHVACinstalleroptionstofactorydefault(onlydate
and time settings are retained) and remove from Lutron®
system
0900* Lutron System
Connection
0 Remove from Lutron system
1 Connected
*Note: Option only visible when connected to a Lutron system.