User's Manual

1
When using controls in single location installations, tighten the blue terminal without
any wires attached. DO NOT connect the blue terminal to any other wiring or to
ground.
2
Up to 9 Remote Dimmers / Switches may be connected to a Dimmer / Switch. Total blue
terminal wire length may be up to 250 ft (76 m).
3
Neutral wire Dimmers / Switches must be connected on the Load side of a multi-
location installation.
Designer-Style RF Maestro®
Dimmers: RRD-6D, -6NA, -10D, -10ND
Switch: RRD-8ANS
Typical Power Consumption*: 0.2 W
Remote Dimmer: RD-RD
Remote Switch: RD-RS
Typical Power Consumption*: 0 W
120 V 50 / 60 Hz
Installation Instructions
Please Read Before Installing
Multigang Installations
In multigang installations, several controls
are grouped horizontally in one multigang
wallbox.
When combining controls in a wallbox,
derating is required; however, no derating
is required for Remote Dimmers / Switches.
Derating Chart
Control Load
Type
End of
Gang
Middle of
Gang
-6D
Incand. 500 W 400 W
MLV
400 W /
500 VA
300 W /
400 VA
-6NA
Incand./
ELV
500 W 400 W
MLV
400 W /
500 VA
300 W /
400 VA
-10D,
-10ND
Incand. 800 W 650 W
MLV
600 W /
800 VA
500 W /
650 VA
-8ANS
Lighting 6.5 A 5 A
Motor
1/4 HP
5.8 A
1/6 HP
4.4 A
Note: -8ANS controls have fins that need
to be removed for multigang installations.
-6D, -6NA, -10D, -10ND, -RD and -RS
controls do not have fins that need to be
removed for multigang installations.
Multi-Location Installation without Neutral
2
-6D and -10D with RD-RD
Wiring Diagram 1b
Single Location Installation with Neutral
1
-6NA, -10ND, and -8ANS
120 V
50 / 60 Hz
Brass
Silver
Black
Blue
Tighten
1
Green
Ground
Hot/Live
Neutral
Load
Wiring Diagram 2a
Single Location Installation without Neutral
1
-6D and -10D
Wiring Diagram 1a
Multi-Location Installation with Neutral
2, 3
-6NA and -10ND with RD-RD, and -8ANS with RD-RS
Dimmer / Switch
Status LEDs (Dimmer Only)
Indicate light level; glows softly as
night light when load is off
Tapswitch
Tap on/off
Dimming Rocker
Press to Brighten
Press to Dim
FASS
TM
Front
Accessible
Service
Switch
Dimmer Operation
Switch Operation
Lamp Replacement
WARNING - Shock Hazard - For any procedure other than routine lamp
replacement, power must be disconnected at the main electrical panel. Working
with power ON could result in serious injury or even death.
For your safety during routine lamp replacement, remove power from the fixture(s) by pulling
the FASS switch out on both the Dimmer / Switch and all Remote Dimmers / Switches.
Troubleshooting Guide
Lutron Elec tron ics Co., Inc.
7200 Suter Road
Coopersburg, PA 18036-1299
Print ed in the U.S.A. 01 / 11 P/N 044-264 Rev. A
Dimmer
Status LED (Switch Only)
Indicates light status; glows softly
as night light when load is off
Tapswitch
Tap on/off
FASS
Front
Accessible
Service
Switch
Brass
Black
Blue
Tighten
1
Green
Ground
Hot/Live
Neutral
Lighting
Load
Dimmer
Brass
Black
Blue
Green
Ground
Lighting
Load
Dimmer or
Remote Dimmer
Brass
Black
Blue
Green
Ground
Remote Dimmer
or Dimmer
120 V
50 / 60 Hz
Brass
Black
Blue
Green
Ground
Hot/Live
Neutral
Remote Dimmer
or Dimmer
Brass
Silver
Black
Blue
Green
Ground
Load
Brass
Black
Blue
Green
Ground
Remote Dimmer/Switch
120 V
50 / 60 Hz
Brass
Black
Blue
Green
Ground
Hot/Live
Neutral
Remote Dimmer/Switch
Dimmer / Switch
Wiring Diagram 2b
Switch
120 V
50 / 60 Hz
Screw Terminals: use
with 12 AWG (2.5 mm
2
) or
14 AWG (1.5 mm
2
) solid
copper wire only. DO NOT
use stranded or twisted
wire.
Wrap wire around screw
terminal. Tighten securely
to 5 in-lbs (0.55 N•m).
b. Wire Connectors:
Prepare wires. When making
wire connections, follow the
recommended strip lengths and
combinations for the supplied wire
connector.
Note: Wire connector provided is
suitable for copper wire only.
Wire Connector:
Strip insulation 3/8 in (10 mm) for
14 AWG (1.5 mm
2
) or 12 AWG
(2.5 mm
2
) wire
Strip insulation 7/16 in (11 mm) for
18 AWG (0.75 mm
2
) wire
Use to join one or two 14 AWG
(1.5 mm
2
) or 12 AWG
(2.5 mm
2
) wires
with one 18 AWG (0.75 mm
2
) ground
wire.
For installations WITHOUT a neutral
wire: See Wiring Diagram 1a or 1b.
For installations WITH a neutral wire:
See Wiring Diagrams 2a or 2b.
Note: If a neutral wire connection
is available, connect it to the silver
terminal.
4. Push all wires back into the wallbox and
loosely fasten the control to the wallbox
using the control mounting screws
provided. Do not pinch the wires.
5. Attach the Lutron Claro or Satin Colors
wallplate adapter and wallplate.
a. Install wallplate adapter onto front of
control(s).
b. Tighten control mounting screws until
wallplate adapter is flush to wall (do
not over-tighten).
c. Snap wallplate onto wallplate adapter,
and verify that control is aligned
properly.
d. If controls are misaligned, loosen
mounting screws appropriately.
6. Restore power. Verify correct local
operation (see Dimmer Operation and
Switch Operation).
Symptom Probable Cause and Action
Lights don’t switch
ON / OFF when
Tapswitch on
Dimmer / Switch/
Remote is pressed
Power not present
Circuit breaker OFF or tripped. Perform Short Circuit Check.
FASS is in the OFF position. Move FASS to the ON position
by fully pushing it in. Check both the Dimmer / Switch and all
of the Remote Dimmers / Switches.
Wiring
Wires shorted. Make sure the blue terminal is not grounded
or shorted to any other wires.
Wiring error. Check wiring to be sure it agrees with
installation instructions and wiring diagrams.
Increase load to meet the appropriate minimum load
requirement. See Load Specifications.
Lamps burned out or not installed
Replace or install lamps.
Dioded lamps
If dioded lamps are being used, replace with non-dioded
lamps.
Light turns ON and
OFF continuously
or lights turn ON
when Tapswitch is
pressed, then turn
OFF
Load is less than minimum load requirement
Make sure the connected load meets the appropriate
minimum load requirement for that control. See Load
Specifications.
Lights don’t switch
ON/OFF from a
Keypad
Improper programming
Program according to the system Setup Guide.
Out of RF range
Reposition to be within 30 ft (9 m) of an RF Signal Repeater.
Wiring
Wires shorted. Make sure the blue terminal is not grounded
or shorted to any other wires.
Wiring error. Check wiring to be sure it agrees with
installation instructions and wiring diagrams.
Wallplate is warm Solid-state control dissipation
Solid-state dimmers and switches internally dissipate about
2% of the total connected load. It is normal for dimmers and
switches to feel warm to the touch during operation.
Note: Refer to the system Setup Guide for additional troubleshooting
suggestions.
Use these instructions to install the
model numbers listed above. For system
setup instructions and tools visit
www.lutron.com/radiora2
Load Specifications:
Control Load
Type
Min.
Load
Max.
Load
-6D
1
Incand. 50 W 600 W
MLV
2
50 W / VA
450 W /
600 VA
-6NA
1
Incand./
ELV
2 5 W 600 W
MLV
2
5 W / VA
450 W /
600 VA
-10D
1
Incand. 50 W 1000 W
MLV
2
50 W / VA
800 W /
1000 VA
-10ND
1
Incand. 10 W 1000 W
MLV
2
10 W / VA
800 W /
1000 VA
-8ANS
3
Lighting 10 W / VA 8 A
Motor 0.08 A
1/4 HP
5.8 A
-RD See Dimmer 8.3 A
-RS See Switch 8.3 A
1 Dimmer Load Type: -6D, -10D and -10ND are
designed for use with permanently installed
incandescent, magnetic low-voltage, or
tungsten halogen only.
-6NA is designed for use with permanently
installed incandescent, electronic low-voltage,
magnetic low-voltage, or tungsten halogen only.
Do not install dimmers to control receptacles or
motor-operated appliances.
2 Low-Voltage Applications: Use -6D,
-10D and -10ND with magnetic (core and coil)
low-voltage transformers only. Not for use with
electronic (solid-state) low-voltage transformers.
Use -6NA with electronic (solid-state) or
magnetic (core and coil) transformers.
Operation of a low-voltage circuit with lamps
inoperative or removed may result in transformer
overheating and premature failure. Lutron
strongly recommends the following:
a. Do not operate low-voltage circuits without
operative lamps in place.
b. Replace burned-out lamps as quickly as
possible.
c. Use transformers that incorporate thermal
protection or fused transformer primary
windings to prevent transformer failure due to
overcurrent.
3 Switch Load Type: -8ANS is designed for
use with permanently installed incandescent,
magnetic low-voltage, electronic low-voltage,
or fluorescent loads and with motor loads up to
1/4 HP (5.8 A).
Important Notes
WARNING - Entrapment Hazard -
To avoid the risk of entrapment,
serious injury, or death, these
controls must not be used to control
equipment which is not visible from every
control location or which could create
hazardous situations such as entrapment
if operated accidentally. Examples of such
equipment which must not be operated
by these controls include (but are not
limited to) motorized gates, garage doors,
industrial doors, microwave ovens, heating
pads, etc. It is the installer’s responsibility
to ensure that the equipment being
controlled is visible from every control
location and that only suitable equipment
is connected to these controls. Failure
to do so could result in serious injury or
death.
Codes: Install in accordance with all local
and national electrical codes.
Grounding: When no “grounding means”
exist within the wallbox, then the NEC
®
2008, Article 404.9 allows a dimmer
without a grounding connection to be
installed as a replacement, as long as a
plastic, noncombustible wallplate is used.
For this type of installation, cap or remove
the green ground wire on the dimmer
and use an appropriate wallplate such as
Lutron
® Claro® or Satin Colors® wallplates.
Neutral Wire: -6NA, -10ND, and -8ANS
require a neutral wire connection in the
wallbox where the Dimmer/Switch is to be
installed. If a neutral wire connection is not
available in the wallbox, contact a licensed
electrician for installation.
Environment:
Ambient operating
temperature: 32 °F to 104 °F (0 °C to 40 °C),
0% to 90% humidity, non-condensing. Indoor
use only.
Spacing: If mounting one control above
another, leave at least
4
½
in (114 mm)
vertical space between them.
Wallplates: Lutron
® Claro and Satin Colors
wallplates are recommended for best color
match and aesthetic appearance. Do not
paint controls or wallplates.
Cleaning: To clean, wipe with a clean
damp cloth. DO NOT use any chemical
cleaning solutions.
Wallboxes: Lutron recommends using
3
½
in (89 mm) deep wallboxes for easier
installation. Several controls may be
installed in one multigang wallbox. See
Derating Chart.
Remote Dimmers / Switches: Use only
Remote Dimmers (RD-RD) with -6D,
-6NA, -10D, and -10ND controls. Use only
Remote Switches (RD-RS) with -8ANS
controls. Up to 9 -RD or -RS controls
may be used with Dimmers or Switches.
Mechanical 3- or 4-way switches will not
work
RF Device Placement: RF Dimmers and
Switches must be located within 30 ft
(9 m) of an RF signal repeater. Remote
Dimmers and Switches are not required to
be within a specific range of a repeater.
For systems with an RF signal repeater, RF
Dimmers or Switches cannot be controlled
by the system until they are programmed
in a system according to the system Setup
Guide.
English
Remote
Dimmer
Remote
Switch
NEC is a registered trademark of the National Fire Protection Association, Quincy, Massachusetts. Lutron, Claro, Satin Colors, Maestro, RadioRA and the sunburst logo are registered trademarks and RadioRA 2 and
FASS are trademarks of Lutron Electronics Co., Inc.
©2011 Lutron Electronics Co., Inc.
Mounting Diagram
Control
Mounting
Screws
Wallbox
Control
Included:
Wire Connector (1)
Mounting Screws (2)
Adapter
Mounting
Screws
Wallplate adapter and
wallplate purchased
separately.
1. Turn power OFF at fusebox or circuit
breaker.
2. Check the installation for short circuits
before installing control(s). With power
OFF, install standard mechanical
switch(es) between Hot and load.
Restore power. If lights do not work or
a breaker trips, check wiring. Correct
wiring and check again. Install control(s)
only when short is no longer present.
Warranty is void if control is turned ON
with a shorted circuit.
3. Wire controls according to one of the
following options:
a. Terminals:
Trim or strip wallbox wires to the length
indicated by the strip gauge on the back
of the control.
Push-In Terminals: Use
with
14 AWG (1.5 mm
2
)
solid copper wire only.
DO NOT use stranded or
twisted wire.
Insert wires fully. To
release wire, insert small,
flat screwdriver into slot
below push-in terminal.
Push screwdriver in while
pulling wire out.
OR
Removing Fins on -8ANS
Each control
has inside
fins removed
Control at middle
of Gang has all fins
removed
Do Not remove outside fins on
Controls at the end of gang
Control Location for Ganging
Installation
WARNING - Shock Hazard -
To avoid the risk of electric shock
locate and remove fuse or lock
circuit breaker in the OFF position before
proceeding. Wiring with power ON could
result in serious injury or death.
Returning Dimmers / Switches to Factory Settings
Note: Returning a dimmer / switch to its factory settings will remove it from the system and
erase all programming from it.
Step 1 : Triple tap the tapswitch on a dimmer / switch. DO NOT release after the third tap.
Step 2 : Keep the tapswitch pressed on the third tap (for approximately 3 seconds) until
the LEDs on the dimmer start to scroll up and down quickly, or the LED on the
switch flashes quickly
Step 3 : Release the tapswitch and immediately triple tap the tapswitch again. The LEDs
on the dimmer will scroll up and down slowly. The LED on the switch will flash
slowly.
The dimmer / switch has now been returned to factory settings and needs to be
reprogrammed into a system.
Warranty: For warranty information, please see the enclosed Warranty, or visit
www.lutron.com/resiinfo
Technical Assistance:
U.S.A. / Canada: 1.800.523.9466
Mexico: +1.888.235.2910
Other Countries: +1.610.282.3800
24 hours a day, 7 days a week.
* Typical Power Consumption test conditions:
Dimmer: load is off, nightlight mode enabled.
Switch: load is off, nightlight mode enabled.
Remote Dimmer / Switch: load is off.
Twist wire
connector
tight.