LCJ Sensor Installation Revision History 15th July, 2008 Jason Pamphilis • Updates based on Alpha 1.0 feedback 9th July, 2008 Brian Valenta • Added revision history • Updates based on 07.08.2008 review (see meeting minutes) – not complete 07.03.
Important Notes 1. Use only high quality lithium batteries, size CR123, 3V. Do not use rechargeable batteries. Using improperly rated batteries could damage the sensor. 2. Clean control with a soft damp cloth only. Do not use any chemical cleaners. 3. The sensor is intended for indoor use only. Operate in ambient temperatures between 0 °C (32 °F) and 40 °C (104 °F) and 0-99% relative humidity condensing. 4. Do not paint controls. 5.
Overview Pre-Installation (Required) Pre-Installation section covers energizing the sensor. System Setup (Required) System Setup section covers the steps to associate a sensor with a receiver. Sensor Placement Sensor Placement covers the rules for proper sensor placement. Motion Sensor Coverage Testing Motion Sensor Coverage Setup covers the steps to test the motion sense coverage area. Permanent Installation (Required) Permanent Installation covers the steps to securely mount the sensor.
System Setup 1. Turn on the Dimmer. 2. Remove mounting plate. Have sensor in hand. 3. Press and hold the Dimmer’s tap button during this entire step. The LEDs blink one at a time, from the bottom up to the top. After approximately 8 seconds, the LEDs will start to cycle slowly from top to bottom (setup mode). Continue to hold the tap button and go to step 4. 4. While observing the dimmer, press and hold the Sensor Add button until the dimmer’s LEDs chase from top to bottom.
RF Coverage 30 feet Motion Floor Coverage Ceiling Height Motion Floor Coverage Radius Ceiling Height (feet) 8 9 10 12 Motion Floor Coverage Radius (feet) 12 13.5 15 18 *Motion Floor Coverage indicates the area in which the LCJ sensor is capable of detecting motion.
Motion Sensor Coverage Testing 1. Remove sensor from wall-mounting bracket. 2. 3. 4. 5. Press test mode. Replace wall-mounting bracket. Adhere unit to ceiling. Confirm the coverage area by walking in the Sensor space and observe the Lens LED state. The Lens LED in the on state signifies motion detected and the Lens LED in the off state signifies motion not detected. 6. Tweak the sensor coverage area by temporarily mounting in a different location if necessary and repeat this step as necessary. 7.
Permanent Installation 1. Note: Anchor usage is optional. Skip to the next step if not using anchors. 1.1. Drill two 3/16-inch holes for the provided anchors using the mounting bracket as a template. The anchor holes should be across from each other. Anchor Locations Anchor Locations 1.2. Install anchors. 2. Place mounting bracket flush against the wall with the smooth side against the wall and install the two provided screws using a hand screwdriver. NOTICE: Use of a hand screwdriver is recommended.