User's Manual
2
Mounting Diagram
Wallbox
Keypad
Mounting
Screws
Keypad
Adapter
Mounting
Screws
Wallplate and Adapter are purchased separately.
1. Turn power OFF at fusebox or circuit breaker.
Danger - Locate and remove fuse or lock circuit
breaker in the OFF position before proceeding.
Wiring with power ON may result in personal
injury.
2. Prepare wires. When making wire connections, fol-
low the recommended strip lengths and combina-
tions for the supplied wire connectors. Note: Wire
connectors provided are suitable for copper wire
only.
Small:
Strip insulation 3/8 in. (10 mm) for
14 AWG (2.5 mm
2
).
Strip insulation 1/2 in. (13 mm) for
16 AWG (1.5 mm
2
).
Use to join one 14 AWG supply wire with
one 16 or 18 AWG (1.0 mm
2
) control
wire.
3. Wiring: See Wiring Diagram (page 3).
4. Push all wires back into the wallbox and loosely fasten
the control to the wallbox using the keypad mounting
screws provided. Do not pinch the wires.
5. Attach Lutron Claro® or Satin ColorsTM
wallplate
adapter and wallplate.
a. Loosely install keypad mounting screws.
b. Tighten wallplate adapter mounting screws
snug.
c. Tighten keypad mounting screws until
wallplate adapter is flush to wall (do not over-
tighten).
d. Snap wallplate onto wallplate adapter, and
verify that buttons are not submerged.
e. If buttons are submerged, loosen keypad
mounting screws appropriately.
6. Restore power.
Included:
Wire Connectors (3)
Mounting Screws (2)
Installation
Small